30 Wistar rats and analysed histologically (at three and six weeks

postoperatively) for their ability to induce newectopic bone forma-

tion around grafted material. A semi-quantitative osteoinductive

score was used to quantify the osteoinductive ability of both bone

grafts.

Results:

The results reveal that the FYRTOB bone graft pos-

sessed 2.1 times higher osteoinductive potential in comparison

with autogenous bone.

Conclusion:

These findings suggest that FYRTOB bone grafts

have potential for inducing ectopic bone formation. Future clinical

testing is necessary to reveal their bone-inducing properties in

different clinical scenarios.

http://dx.doi.org/10.1016/j.ijom.2017.02.919

Effects of bone density and inclination of implant on

micromotion at the bone-implant interface

T. Sugiura

∗

, K. Yamamoto, S. Horita, K. Murakami, T. Kirita

Department of Oral and Maxillofacial Surgery, Nara Medical

University, Nara, Japan

Background:

Primary stability is one of the most important vari-

ables affecting the success of immediately loaded implants. There

have been no studies evaluating the correlation between the bone

types and the primary stability of immediately loaded implants

according to the “All-on-Four” concept (Ao4 model).

Objectives:

The purpose of this studywas to investigate the effects

of bone density and crestal cortical bone thickness as well as incli-

nation of implant onmicromotion of immediately loaded implants.

Methods:

A three-dimensional finite element model of an eden-

tulous mandible was constructed. Four parallel implants were

equally spaced between the bilateral mental foramen (4PI model)

or four implants were placed according to Ao4 model. A frame-

work made of acrylic resin between the bilateral first molars was

modelled. The contact interface between the implant and bone

was simulated. A vertical load of 200 N was applied at the can-

tilever or on the abutments region of the distal implants, simulating

the absence of a cantilever. Micromotion (relative displacement

between the implant and bone) was calculated.

Findings and Conclusion:

The maximum micromotions with

low-density cancellous bone were approximately five-fold higher

than those with high-density cancellous bone. Maximum micro-

motion in the Ao4 models resulted in 28–68% decrease compared

with 4PI models. Cancellous bone density and loading position

may be a critical factor for avoiding excessive micromotion in

immediately loaded implants. Ao4 configuration can significantly

decrease the maximum micromotion compared with parallel

implant configuration because of reduced cantilever length.

http://dx.doi.org/10.1016/j.ijom.2017.02.920

Acute infection and numbness following dental implant

placement using the flapless technique

S. Sujesh

∗

, A.R. Zainal, W.C. Ngeow

University Malaya, Kuala Lumpur, Malaysia

Background:

Acute onset of infection and numbness arising after

dental implant placement are rare but not uncommon compli-

cations. Studies have reported that 4–10% of patients receiving

dental implants develop postoperative infections which hamper

osteointegration and leads to implant failure.

Objective:

The aim of this article is to report the incidence of

a postoperative right submandibular swelling and right mental

region numbness occurring 48 h post implant placement using

a flapless technique. The patient noticed swelling of the right

submandibular region 2 days after implant placement, which

was associated with excruciating pain and fever. The swelling

gradually increased in size despite the administration of oral

antibiotic with pus seen discharging around the vicinity of implant

when palpated. Pus swab revealed the isolation of

Streptococcus

parasanguinis

,

Neisseria

spp. and

Klebsiella

spp. The sensation

of pain at the implant site and submandibular region overwhelmed

the numbness felt at the right mental region, which was caused by

the implant impinging onto the inferior alveolar nerve. However,

numbness became prominent and persisted after controlling the

infection and removing the offending implant.

Conclusion:

A rare case of acute infection that presented as a

submandibular swelling coupled with the sensation of numbness

at the right mental region after implant placement is presented.

These symptoms lead to detrimental quality of life for the patient

at one-month post-explantation.

http://dx.doi.org/10.1016/j.ijom.2017.02.921

Correlation between nasal decongestant use and maxillary

sinus perforation: a retrospective study

S. Swaroop

∗

, M. Milder, A. Vishwanath, D. Chang

Oral and Maxillofacial Surgery Department, Tufts University

School of Dental Medicine, Boston, United States

Background:

Perforation of the Schneiderianmembrane is a com-

mon complication during external sinus augmentation procedure,

which may be at a higher risk in patients using steroidal nasal

spray. Research has shown a statistically significant decrease in

the thickness in the inferior turbinate of nasal epithelium after 6

months

. 1 S

imilarly, steroidal nasal spray would make the mem-

brane thin and brittle, which may increase risk for perforation;

however, there is no published data yet.

Objective:

The objective is to explore whether history of steroid

nasal spray increases the risk of perforation of the Schneiderian

membrane. The outcomes of this study will allow practitioners to

be cautious or alter the procedure method and/or treatment plan.

Methods:

This retrospective study was conducted at the Tufts

University School of Dental Medicine. Following the institutional

review board approval, clinical records of the patients who under-

went external sinus lifts at the Oral and Maxillofacial Surgery

Resident Clinic in the past five years were reviewed.

Results:

A total of 76 patients underwent this procedure. Only

11 (14.5%) patients had documented history of steroid nasal

decongestant spray. There were a total of 29 (36.8%) perfora-

tions documented and among themonly five (45.5%) patients were

using nasal spray.

Conclusions:

This is an ongoing study and results from this pre-

liminary analysis show that there is no correlation between steroid

nasal decongestant spray and the risk of perforation of the Schnei-

derian membrane.