Methods:
The medical–technical model included ultrasonic gen-
erator, fixtures for implant samples, camcorder and Petri dish with
sterile 0.9% physiological solution, and allowed simultaneous
immersion of apical part of test and control implants into wet-
ting solution. Empirically the base resonant frequency for given
size of implants was found. Ultrasonication of implants with found
frequency allowed “forced wetting” of implant surface.
Findings:
Results of experiment showed that application of ultra-
sound with resonant frequency to dental implants caused “forced
wetting” of the surface of all the test samples (32 dental implants
with SLA surface) within 5–7 s. Surface wetting of control sam-
ples (32 dental implant with SLA surface) was not observed. We
assume, that effect of “forced wetting” of dental implant surface
is possible due to increase of surface energy caused by ultrasound
application, which destroys surface tension of wetting agent.
Conclusion:
Based on the performed experimental studies it can
be concluded, that ultrasonic application to dental implants could
increase their surfacewettability, especially in porous and complex
surfaces with micro- and nanotopography.
http://dx.doi.org/10.1016/j.ijom.2017.02.909Histomorphometric results of low-intensity pulsed
ultrasound application in dental implantation
I. Khomich
∗
, S. Rubnikovich, S. Khomich, A. Khomich
Belarusian State Medical Academy of Postgraduate Education,
Minsk, Belarus
Background:
Studies show that osteoreparation processes
proceed more intensively at sites with low-intensity pulsed ultra-
sound (LIPUS) application to 47.2–66.8% (
P
< 0.001) compared
to the ones without.
Objectives:
To evaluate histomorphometric changes around den-
tal implants after ultrasound application in the early healing stages.
Methods:
Histomorphometric evaluation of periimplant bone tis-
sue with and without LIPUS was performed.
Findings:
In animal models without LIPUS at all stages of the
experiment trabecular bone area with high density of osteogenic
cells was significantly lower (Mann-Whitney
U
Test,
P
< 0.05)
than in group with LIPUS application to implants and periimplant
tissues. The area of newly formed bone around the implant bed
was significantly higher (up to 25.6–36.5% (
P
< 0.001)) in animal
models with LIPUS exposure comparing to the ones without. The
combined effect of LIPUS on implants and periimplant tissues has
expressed a linear relationship (
R
= 0.96)–and resulted in marked
increase of the area of active osteoblastic surface (
P
= 0.0332).
Newly formed coarse fibre and lamellar bone tissue formation
was observed around implant bed in LIPUS group. In the control
group there was a delay of bone maturation and the predominance
of coarse-fibered bone tissue at a later terms of osteosynthesis
compared to LIPUS group.
Conclusion:
We assume that the combined effect of LIPUS on
dental implants and periimplant tissues improves osteoreparation
and osseointegration processes.
http://dx.doi.org/10.1016/j.ijom.2017.02.910Results of morphological studies on the effectiveness of
dental implantation using low-intensity pulsed ultrasound
I. Khomich
∗
, S. Rubnikovich, S. Khomich, A. Khomich
Belarusian State Medical Academy of Postgraduate Education,
Minsk, Belarus
Background:
Ultrasound application to bone fractures in early
stages has shown acceleration of callus formation and ossification
in several studies.
Objectives:
To study the morphological changes around installed
dental implants after ultrasound application in the early healing
stages.
Methods:
In all experimental groups osseointegration processes
took place without breaking the sequence of reparation stages.
However, the timing and extent of the repair and osseointegration
in the control and experimental groups differed depending on the
therapeutic effects of the methods.
Findings:
Delay of bone maturation, presence of necrotic zones,
immature granulation tissue in the early stages, and the pre-
dominance of coarse-fibered bone tissue at a later stage of
osteosynthesis were found in the first group. In the second group
application of low-intensity pulsed ultrasound (LIPUS) to dental
implants and periimplant tissues of the operated area contributed
to the formation of bone tissue similar in histostructure to the par-
ent bone. The area of the newly formed periimplant bone tissue
in the group with LIPUS was significantly higher than that in the
first group at all stages of the experiment.
Conclusion:
The use of LIPUS during dental implantation induces
osteoreparation processes by stimulating angiogenesis in the gran-
ulation and the newly formed bone.
http://dx.doi.org/10.1016/j.ijom.2017.02.911Clinical outcome of implants and sinus bone grafts in the
case of maxillary sinusitis: retrospective clinical study
H.S. Kim
∗
, J.K. Ku, Y.K. Kim
Department of Oral and Maxillofacial Surgery, Seoul National
University Bundang Hospital, Seongnam, Korea
Objectives:
To evaluate clinical outcome of implants and sinus
bone grafts in maxillary sinusitis patients.
Methods:
This study included 29 patients (59 implants) who
contracted maxillary sinusitis before or after sinus bone graft
or implantation. Treatment cases were categorised into three
groups according to the time of sinusitis treatment, bone graft and
implantation; Group I (
n
= 18): maxillary sinusitis treated before
bone graft and implantation, Group II (
n
= 22): maxillary sinusitis
treated after bone graft, but before implantation, and Group III
(
n
= 19): maxillary sinusitis treated after bone graft and implanta-
tion. Among the groups, mean marginal bone loss (MBL), survival
rate, sinus membrane perforation at bone graft, relationship with
smoke, primary and secondary stabilities of implant were evalu-
ated.
Findings:
During average observation period of 70.58 months,
Group II showed significantly more MBL than Group I and III
(
P
< 0.05). The implant survival rates of Group I (94.44
±
0.24%)
and Group III (89.47
±
0.32%) were significantly higher than
that of Group II (63.16
±
0.50%;
P
< 0.001). Group II showed
dominant frequency in sinus membrane perforation at bone graft