Preparation of large maxillary sinus membrane perforation

using a collagen membrane: retrospective clinical study

D.W. Kang

∗

, Y.K. Kim, P.Y. Yun

Department of Oral and Maxillofacial Surgery, Seoul National

University Bundang Hospital, Seongnam, South Korea

Objectives:

To evaluate the clinical outcomes of repairing max-

illary sinus using a collagen membrane, when a large perforation

occurs in the course of a sinus lift.

Methods:

This study included 18 patients who occurred a large

perforation in the course of a sinus lift at the Seoul National Uni-

versity Bundang Hospital, South Korea, between September 2011

and March 2014 (11 males, 7 females; mean age, 55.1

±

12.3

years; 19 implants). The perforations were repaired by using tissue

additives and collagen membranes, and then sinus bone graft and

implant placement were performed. The resorption of sinus bone

graft, marginal bone loss around the implants, and complications

were assessed.

Findings:

The average resorption of bone graft materials to eval-

uate possible case after one year was 2.99

±

1.06 mm (19 cases),

after two years was 5.28

±

2.43 mm (8 cases) and after three

years was 6.39

±

2.88 mm (8 cases). The total average observa-

tion period of the patients was 27.5

±

17.67 months and the final

average absorption was 4.76

±

2.96 mm. The number of post-

operative complications was 8 of 18 patients. Screw loosening,

periimplantitis, pain, prosthesis dislodgement, haematoma, sinus-

itis, and bleeding were observed. Implant survival rate was 100%

until the final follow-up period. The final alveolar bone resorption

was 1.67

±

1.36 mm around the implant.

Conclusion:

The reparation of large maxillary sinus perforation

using collagen membrane is effective and successful treatment.

http://dx.doi.org/10.1016/j.ijom.2017.02.906

Affinity of octacalcium phosphate collagen composite for

titanium dental implants

T. Kawai

∗

, K. Matsui, Y. Ezoe, F. Kajii, O. Suzuki,

T. Takahashi, S. Kamakura

Division of Oral and Maxillofacial Surgery, Tohoku University

Graduate School of Dentistry, Sendai, Japan

Background and Objective:

Octacalcium phosphate (OCP) and

its collagen composite (OCP/collagen) are good bone substitute

materials. We previously showed that OCP/collagen can be used to

repair human jaw bone defects without any associated abnormal-

ities. The present study investigated whether OCP/collagen could

be applied to dental implant treatment using a dog tooth extraction

socket model.

Methods:

OCP/collagen was prepared as previously described.

The second and third premolars were extracted from bilateral

mandibles of dogs; each extraction socket was extended, and tita-

nium dental implants were placed in each socket. OCP/collagen

was inserted in the space around a titanium dental implant. Autol-

ogous bone and beta-tricalcium phosphate ( -TCP) were used

to fill two of the other sockets, while the untreated socket (i.e.

no bone substitute material) served as a control. Three months

after the operation, we examined the osseointegration of each bone

substitute material with the surface of the titanium dental implant.

Results:

Radiographic and histological evaluation revealed bone

formation around implants in sockets containing OCP/collagen,

autologous bone or -TCP. In histomorphometric analyses, the

periimplant bone areas (BA) percentage and bone-implant contact

(BIC) percentage were measured. There was no difference in BA

percentage between OCP/collagen, autologous bone, and -TCP;

however, BIC percentage differed significantly between the three

materials, although not between OCP/collagen and autologous

bone.

Conclusion:

These results demonstrate that OCP/collagen is a

good alternative to autologous bone as a bone substitute material

in dental implant treatment.

http://dx.doi.org/10.1016/j.ijom.2017.02.907

Elimination of deformities of alveolar processes and

dentition with the use of mini implants

A. Khomich

∗

, I. Khomich, S. Khomich

Belarussian State Medical University, Belarus

Background:

In many clinical cases it is difficult, and sometimes

impossible, to eliminate deformations of dentition and alveolar

processes only by means of orthodontic or surgical treatment.

Therefore, in order to implement an effective movement of the

teeth and surrounding tissues, it is often necessary to use minis-

crews for better, and often the only possible, support.

Objectives:

To analyse methods of eliminating deformations of

the alveolar processes and dentition in patients using miniscrews.

Methods:

Treatment of patients with deformities of alveolar pro-

cesses of upper and lower jaws included orthodontic treatment

with brackets and additional anchorage on miniscrews, sometimes

the movement was carried out only by miniscrews and elastics.

In some cases the procedure was supplemented by compact-

osteotomy. Taperedminiscrews were used and loaded immediately

after installation. In cases with implant loosening, they were rein-

stalled at a new location.

Findings:

Duration of treatment depended on the severity of defor-

mation. The best effect was achieved when installing implants on

both sides of the alveolar process. Use of miniscrews provides

faster and more effective result in eliminating deformations.

Conclusion:

Elimination of deformations of dentition and alve-

olar processes with the use of orthodontic miniimplants goes on

faster and without unwanted movement of adjacent teeth.

http://dx.doi.org/10.1016/j.ijom.2017.02.908

Experimental studies of the effect of low frequency

ultrasound on the wettability of the surface of titanium

dental implants

I. Khomich

∗

, S. Rubnikovich, S. Khomich, A. Khomich

Belarusian State Medical Academy of Postgraduate Education,

Minsk, Belarus

Background:

It is known that wettability of dental implant surface

is one of the key factors influencing quality of osseointegration.

Objectives:

To study the effect of low-intensity pulsed ultrasound

on the wettability of the surface of titanium dental implants in

experimental medical-technical model.