Anterior mandibular bone grafts by submental approach

J. Guiol

∗

, J.F. Tulasne

University Hospital Nantes, France

Background:

Some cases of totally edentulous mandibles are

associated with extreme osseous resorption, which do not allow

the placement of dental implants, even in the symphysis area. In

these cases, bone reconstruction techniques are limited by the risk

of gingival tear and graft exposure.

Technical Note:

The bone graft technique with a submental

approach avoids an intraoral break and the risk of graft exposure

or infection. The reconstruction was done with calvarian bone

apposition in the mandibular interforaminal region. The graft was

generally placed on the upper surface of the symphysis and occa-

sionally on the underside. The scar was hidden in the submental

fold.

Discussion:

We believe this surgical technique is mainly indicated

for cases with extreme bone resorption. It allows the reconstruc-

tion of the mandibular symphysis, without an intraoral approach.

The postoperative courses are uneventful thanks to the cranial

bone harvesting technique. This approach can also be indicated

for elderly patients who complain about ill-fitting dentures.

http://dx.doi.org/10.1016/j.ijom.2017.02.902

No periimplantitis case ever seen!

F. Hernández Altemir

∗

, S. Hernández Montero,

S. Hernández Montero, E. Hernández Montero

Private Institute, Zaragoza, Spain

Background:

For the time being, we have never observed inflam-

matory or similar effects within the structure of titanium implants.

Objectives:

We would like to question the validity of the terms

implantitis/periimplantitis as we believe that inflammatory pro-

cess cannot exist within the structure of the implant device. Should

the term refer to processes around the implant, other terms would

potentially need to be used.

Methods:

Our clinical practice with implants started in

1961–1962. At that time, the concept of osseointegration was not

observed and the work involved implant types different from tita-

nium. When both (osseointegration and titanium) came together,

the current era appeared. Evolution brought us to periimplantitis

and also to everything surrounding the referred term. Large mate-

rial for study exists, both clinical and bibliographic, and therefore

many studies could be performed. We wonder though, whether it

would be possible to speak about a physiopathology of the osseo

de-integration and try to understand even better the aspects of peri-

implantary illness. Researchers have the environment needed for

their practice and that allows the comparison among implantary

phenomena and the one derived from the dental physiopathology:

perception of mucosa inflammation related to gum inflammation

related to implants, leading to mucositis. Same rational made that

periimplantary inflammation led to implantitis/periimplantitis.

Findings and Conclusion:

Our practice with official devices

could not prove inflammatory signs within the device; this triggers

our concern about the terminology used.

http://dx.doi.org/10.1016/j.ijom.2017.02.903

Biomechanical analysis of immediately loaded implants

according to the all-on-four concept

S. Horita

∗

, T. Sugiura, K. Yamamoto, K. Murakami, T. Kirita

Department of Oral and Maxillofacial Surgery, Nara Medical

University, Nara, Japan

Background:

The All-on-Four concept offers a less invasive

option because it requires fewer implants, with bilateral distal

implants inserted at an inclination of 30

◦

to decrease the cantilever

length. However, there has been little biomechanical evidence for

immediately loaded implants according to the All-on-Four con-

cept.

Objectives:

The purpose of this study was to investigate the

biomechanical behaviour of immediately loaded implants in an

edentulous mandible according to the All-on-Four concept.

Methods:

A three-dimensional finite-element model of an eden-

tulous mandible was constructed. Four implants were placed

between the bilateral mental foramen according to All-on-Four

concept. A framework made of titanium or acrylic resin between

the bilateral first molars was modelled. Immediate loading and a

delayed loading protocol were simulated. A vertical load of 200 N

was applied at the cantilever or on the abutments region of the

distal implants, simulating the absence of a cantilever.

Findings and Conclusion:

The loading position greatly affected

the principal compressive and tensile strain values. The peak prin-

cipal compressive strains in non-cantilever loading resulted in a

45.3–52.6% reduction compared with those in cantilever load-

ing. Mandibular fixed full-arch prostheses without cantilevers may

result in a favourable reduction of the periimplant bone strain

during the healing period, compared with cantilevers. The maxi-

mummicromotion was within the acceptable limits for uneventful

implant osseointegration in the immediate loadingmodels. Frame-

work material did not play an important role in reducing the

periimplant bone strain andmicromotion at the bone-implant inter-

face.

http://dx.doi.org/10.1016/j.ijom.2017.02.904

Treatment with short zirconium-oxide implants

S. Jank

Department of Oral and Maxillofacial Surgery, Medical

University of Innsbruck, Austria

Zirconium-oxide implants in maxillofacial surgery are a grow-

ing market. Regarding titanium implants, there is a tendency

to short implants to avoid augmentation. Regarding zirconium

implants, the manufacturers and the users are still more conserva-

tive regarding diameter and length of the implants.

In this case-report, a patient is presented, receiving an implant

with a length of 6 mm.

No problems regarding osseointegration and healing occurred.

The implant presented stable after 3 months, therefore the dentist

could continue with prosthetic reconstruction.

Studies with a bigger number of patients are required to prove

the potential of short zirconium oxide implants in comparison to

titanium.