268
Anterior mandibular bone grafts by submental approach
J. Guiol
∗
, J.F. Tulasne
University Hospital Nantes, France
Background:
Some cases of totally edentulous mandibles are
associated with extreme osseous resorption, which do not allow
the placement of dental implants, even in the symphysis area. In
these cases, bone reconstruction techniques are limited by the risk
of gingival tear and graft exposure.
Technical Note:
The bone graft technique with a submental
approach avoids an intraoral break and the risk of graft exposure
or infection. The reconstruction was done with calvarian bone
apposition in the mandibular interforaminal region. The graft was
generally placed on the upper surface of the symphysis and occa-
sionally on the underside. The scar was hidden in the submental
fold.
Discussion:
We believe this surgical technique is mainly indicated
for cases with extreme bone resorption. It allows the reconstruc-
tion of the mandibular symphysis, without an intraoral approach.
The postoperative courses are uneventful thanks to the cranial
bone harvesting technique. This approach can also be indicated
for elderly patients who complain about ill-fitting dentures.
http://dx.doi.org/10.1016/j.ijom.2017.02.902No periimplantitis case ever seen!
F. Hernández Altemir
∗
, S. Hernández Montero,
S. Hernández Montero, E. Hernández Montero
Private Institute, Zaragoza, Spain
Background:
For the time being, we have never observed inflam-
matory or similar effects within the structure of titanium implants.
Objectives:
We would like to question the validity of the terms
implantitis/periimplantitis as we believe that inflammatory pro-
cess cannot exist within the structure of the implant device. Should
the term refer to processes around the implant, other terms would
potentially need to be used.
Methods:
Our clinical practice with implants started in
1961–1962. At that time, the concept of osseointegration was not
observed and the work involved implant types different from tita-
nium. When both (osseointegration and titanium) came together,
the current era appeared. Evolution brought us to periimplantitis
and also to everything surrounding the referred term. Large mate-
rial for study exists, both clinical and bibliographic, and therefore
many studies could be performed. We wonder though, whether it
would be possible to speak about a physiopathology of the osseo
de-integration and try to understand even better the aspects of peri-
implantary illness. Researchers have the environment needed for
their practice and that allows the comparison among implantary
phenomena and the one derived from the dental physiopathology:
perception of mucosa inflammation related to gum inflammation
related to implants, leading to mucositis. Same rational made that
periimplantary inflammation led to implantitis/periimplantitis.
Findings and Conclusion:
Our practice with official devices
could not prove inflammatory signs within the device; this triggers
our concern about the terminology used.
http://dx.doi.org/10.1016/j.ijom.2017.02.903Biomechanical analysis of immediately loaded implants
according to the all-on-four concept
S. Horita
∗
, T. Sugiura, K. Yamamoto, K. Murakami, T. Kirita
Department of Oral and Maxillofacial Surgery, Nara Medical
University, Nara, Japan
Background:
The All-on-Four concept offers a less invasive
option because it requires fewer implants, with bilateral distal
implants inserted at an inclination of 30
◦
to decrease the cantilever
length. However, there has been little biomechanical evidence for
immediately loaded implants according to the All-on-Four con-
cept.
Objectives:
The purpose of this study was to investigate the
biomechanical behaviour of immediately loaded implants in an
edentulous mandible according to the All-on-Four concept.
Methods:
A three-dimensional finite-element model of an eden-
tulous mandible was constructed. Four implants were placed
between the bilateral mental foramen according to All-on-Four
concept. A framework made of titanium or acrylic resin between
the bilateral first molars was modelled. Immediate loading and a
delayed loading protocol were simulated. A vertical load of 200 N
was applied at the cantilever or on the abutments region of the
distal implants, simulating the absence of a cantilever.
Findings and Conclusion:
The loading position greatly affected
the principal compressive and tensile strain values. The peak prin-
cipal compressive strains in non-cantilever loading resulted in a
45.3–52.6% reduction compared with those in cantilever load-
ing. Mandibular fixed full-arch prostheses without cantilevers may
result in a favourable reduction of the periimplant bone strain
during the healing period, compared with cantilevers. The maxi-
mummicromotion was within the acceptable limits for uneventful
implant osseointegration in the immediate loadingmodels. Frame-
work material did not play an important role in reducing the
periimplant bone strain andmicromotion at the bone-implant inter-
face.
http://dx.doi.org/10.1016/j.ijom.2017.02.904Treatment with short zirconium-oxide implants
S. Jank
Department of Oral and Maxillofacial Surgery, Medical
University of Innsbruck, Austria
Zirconium-oxide implants in maxillofacial surgery are a grow-
ing market. Regarding titanium implants, there is a tendency
to short implants to avoid augmentation. Regarding zirconium
implants, the manufacturers and the users are still more conserva-
tive regarding diameter and length of the implants.
In this case-report, a patient is presented, receiving an implant
with a length of 6 mm.
No problems regarding osseointegration and healing occurred.
The implant presented stable after 3 months, therefore the dentist
could continue with prosthetic reconstruction.
Studies with a bigger number of patients are required to prove
the potential of short zirconium oxide implants in comparison to
titanium.
http://dx.doi.org/10.1016/j.ijom.2017.02.905




