Methods:
From 2012 to 2016, 52 patients underwent segmental
mandibular reconstruction with double-barrelled fibular osteosep-
tocutaneous flaps with computer-aided design/computer-aided
manufacturing technic. Preoperative computer tomographic (CT)
scans were imported into Mimics 10.01 software (Materialise,
Leuven, Belgium) for surgical planning. The double-barrelled
bone was strung with 16 mm fixation screws instead of miniplate.
63 dental implants placement were simultaneous in 30 patients
and 32 dental implants placement were in second stage in 18
patients. Postoperative CT and digital imaging were evaluated
to assess surgical accuracy using software. The pre- and post-
operative morphometric measurements were compared using the
Student
t
test.
Results:
Two flaps occurred vascular crisis postoperatively. There
was no flap necrosis. One hundred four CT scans from 52
patients who underwent partial mandibular resection were ana-
lysed. The dimensions of the double-barrelled fibula segments
after osteotomy showed no difference from the preoperative vir-
tual surgical planning (VSP). But the condylar locations showed
a disposition out of the fossa (
P
< 0.05), between VSP and post-
operative CT scans. There was no difference in implants between
VSP and postoperative CT scans.
Conclusions:
The VSP of relationship of double-barrelled fibular
is important for segmental mandible reconstruction. The benefit
of VSP was to enhance surgical accuracy and safety.
http://dx.doi.org/10.1016/j.ijom.2017.02.645Computer-aided design/computer-aided manufacturing
versus conventional fixation methods for mandible
reconstruction: a biomechanical
in vitro
study
C. Rendenbach
∗
, L. Gerbig, G. Huber, K. Sellenschloh,
M. Morlock, R. Smeets, B. Beck-Broichsitter, M. Heiland,
H. Hanken
University Medical Center Hamburg Eppendorf and Technical
University Hamburg, Germany
Background:
There are several methods for osseous fixation
in mandible reconstruction with a trend towards computer-aided
design/computer-aided manufacturing (CAD/CAM) plates. There
a no studies comparing biomechanical aspects of conventional
plates with CAD-CAM fixation systems to date.
Objective:
The aim of this study was to determine the plate with
the highest fatigue strength.
Methods:
We designed a polyurethane mandible reconstruction
model (Synbone, CH) with cortical and cancellous equivalents.
Three different fixation systems with each six specimen were
tested. Mandible reconstruction of a right-sided two-segment
defect was performed with either miniplates (Group A), a con-
ventional 2.0 mm reconstruction plate (Group B) or an individual
CAD-CAM plate (Group C) [Depuy Synthes, Germany]. Masti-
cation was simulated via cyclic dynamic testing using a universal
testing machine (MTS, Bionix, Eden Prairie, MN). Specimens
were tested at a rate of 1 Hz with increasing load application
(+0.15 N/cycle) on the left side.
Findings:
Material failure in the miniplate group occurred at
51.920 simulated bite cycles on average (corresponding to a load of
0.56
±
0.4 kN). CADCAMand reconstruction plates failed at 0.66
and 0.65 kN on average. Material stiffness was higher (+70 N/mm)
in the CAD CAM group. Plate breakage appeared in groups A
and B, while screw breakage was recorded as failure mechanism
in Group C.
Conclusion:
All three tested fixation methods seem sufficiently
stable for mandible reconstruction. For two-segmental defects,
rigid fixation seems to be better in reconstruction plates compared
to titanium miniplates.
http://dx.doi.org/10.1016/j.ijom.2017.02.646L
ong-term biomechanical donor site morbidity after radial
forearm free flap
C. Rendenbach
∗
, C. Kohlmeier, H. Kreiker, A.T. Assaf,
H. Hanken, A. Rashad, R. Smeets, M. Heiland, B. Riecke
University Medical Center Hamburg Eppendorf, Germany
Background:
Although the radial forearm free flap (RFFF) is
a commonly used microvascular graft for head and neck recon-
struction, long-term biomechanical results regarding donor site
morbidity are rare.
Objective:
To evaluate long-term functional outcome after RFFF.
Methods:
In a prospective study 32 patients underwent biome-
chanical assessment preoperatively, three month postoperatively
and two years postoperatively. Both the donor and the contralat-
eral arm were examined. The primary endpoint of the study was
grip strength. Further, Mayo-Wrist-score, DASH-score, finemotor
skill strengths (tip pinch, key pinch, palmar pinch) and the range of
motion were analysed. Primary defects were closed with local full-
thickness skin grafts (FTSG) from the donor site forearm avoiding
a secondary defect site.
Results:
In the long-term analysis, grip strength was reduced in
both arms. A significant improvement over timewas found only for
the donor arm. A persistent deficit of tip pinch strength and dorsal
extension was recorded. Persistent sensory limitations occurred in
4 cases. Patient satisfaction after two years of follow up was high
and daily life routine was not restricted.
Conclusion:
Gross and fine motor skill limitations are reversible
short-term effects after RFFF harvesting and do not restrict daily
routine in the long-term. These findings substantiate the value of
the RFFF as a workhorse reconstructive surgery.
http://dx.doi.org/10.1016/j.ijom.2017.02.647Prefabrication of customised polymethylmethacrylate
implants in cranioplasty and the mechanical properties of
polymethylmethacrylate versus polyetheretherketone
A. Ridwan-Pramana
∗
, J. van Loon, N. Liberton, S. te Slaa,
F. Verver, J. Wolff, T. Forouzanfar
Department of Oral and Maxillofacial Surgery/3D Innovationlab
VU University Medical Center, Amsterdam, The Netherlands
Background:
The two most widely used implant materials in
cranioplasty are polyetheretherketone (PEEK) and polymethyl-
methacrylate (PMMA). PEEK has been used for the last two
decades in cranial surgery, due to its excellent biocompatibility,
good mechanical strength and radiographic translucency. PMMA
has a relatively low cost and has an extensive track record dat-
ing back to the 1940s. Sterilisation is a mandatory process for
materials used in medical applications like skull implants. While
sufficient strength and stiffness are important criteria that implant