186
implant insertions and dental rehabilitation. Surgery and postop-
erative follow-up was uneventful. The patient resumed normal
functions at the first postoperative day, with decrease morbidity
when compared to microvascular grafts. No bone grafts were used.
Conclusion:
The project of this mandible may benefit many oth-
ers patients which sustain serious mandibular defects, providing
less morbidity and allowing for total mandibular and dental reha-
bilitation.
http://dx.doi.org/10.1016/j.ijom.2017.02.635Application of digital and three-dimensional print surgical
guiding plates in free flaps reconstruction of mandible defect
B. Lin
∗
, H.Y. Yang
Peking University Shenzhen Hospital, China
Background:
The three-dimensional (3D) print surgical guiding
plates could be used to assist the mandibular reconstruction.
Objectives:
To establish digital and 3D print surgical guiding
plates in order to provide a comprehensive reconstruction plan
for patients with mandible defect with free fibular flap.
Methods:
Preoperative spirals computed tomography (CT) scan
and 3D reconstruction imaging was taken in 11 patients with
mandibular tumours or defect from 1 September 2015 to 1 March
2016. The stereolithographic model of mandible was made using
RP technique and reverse engineering (RE) from CT data. The
processes of cutting tumour and shaping fibula transplantation
were simulated using Mimics 15.0 software. The surgical guid-
ing plates were devised and incused. Segmental mandibulectomy
and mandibular reconstruction with vascularised fibula were per-
formed based on the preoperative design and guiding plate. All
patients with follow-up were evaluated for postoperative func-
tional and aesthetic results.
Findings:
The method could effectively transfer the virtual surgi-
cal planning information. During operation, the surgical guiding
plates were small and tightly fit with bone tissues without
extending the original surgical incision. Cutting, reformation and
reposition of the fibula could be accelerated by surgical guiding
plates. An average precision of 2 mmwas found for the mandibular
angle region and condyle.
Conclusion:
The surgical guiding plates can enhance the operative
accuracy and improve the surgical effect with good feasibility,
leading to better aesthetic and functional reconstruction outcome
in mandible defect reconstruction.
http://dx.doi.org/10.1016/j.ijom.2017.02.636Visualisation of perforator free flap perfusion in the
immediate postoperative period using spy elite fluorescent
imaging system
A. Massaro
∗
, R. Fernandes, P. Pirgousis, M. Warrick,
A. Bunnell
University of Florida-Jacksonville, FL, United States
Background:
Use of microvascular free flaps for head and neck
reconstruction has reported success rates over 94%. Administra-
tion of intraoperative fluids >7 L has been shown in the literature
to increase the complication rate in head and neck reconstruc-
tion, intraoperative vasopressors are given to assist in limiting
the amount of fluid administration and to counteract vasodila-
tory effects of inhalational and intravenous anaesthetics. However,
concern exists that the use of vasopressors results in periph-
eral vasospasm, reduced flap perfusion, thrombosis and failure.
Despite this belief, vasopressors are routinely administered during
head and neck reconstruction.
Objectives:
Prospective study of 20 reconstructive patients aims
to use SPY Elite Fluorescent Imaging System during the intraop-
erative and immediate postoperative period to assess the potential
effects of inhalational and vasoactive medications administered
intraoperatively on perfusion of perforator free flaps.
Methods:
Perforator free flap were viewed under SPY Elite twice
during the intraoperative period (prior to pedicle division and
after inset) and once in the immediate postoperative period. Type,
concentration of the anaesthetics, type and amount of vasoactive
medications and vital signs were recorded. In the immediate post-
operative period clinical exam and Doppler ultrasound were also
assessed. These time points were compared to ascertain differ-
ences in flap perfusion.
Findings:
Preliminary data shows mild decrease in flap perfusion
in immediate postoperative period when compared to intraopera-
tive period with no significant in change in flap outcomes.
Conclusions:
Flap perfusion during the intraoperative and imme-
diate postoperative periods is nominal with no overall changes in
flap survival.
http://dx.doi.org/10.1016/j.ijom.2017.02.637Microvascular reconstruction in vessel-depleted neck:
alternative vascular options
S. Mattine
Worcester Royal Hospital, United Kingdom
Background:
The commonly used recipient vessels in head and
neck reconstruction are often significantly compromised, non-
viable or absent in patients exposed to previous treatment such
as radiotherapy and/or chemotherapy or surgery.
Methods:
The author aims to present a review of microvascu-
lar reconstruction in this challenging group and formulate an
algorithm for vessel selection, including alternative that are not
considered common practice in head and neck reconstruction.
Results:
Several patients presenting with recurrent malignant
disease or osteoradionecrosis following extensive treatment for
previous head and neck cancer were successfully treated with
microvascular reconstruction.
Our strategy for achieving arterial anastomosis includes explo-
ration and anastomosis with ipsilateral or contralateral neck
vessels if present. Alternatively, the transverse cervical, supras-
capular and superficial temporal arteries were used. Venous
anastomosis was achieved with superficial temporal or innomi-
nate veins when external or internal jugular veins were absent.
Vein grafts were used frequently to lengthen both arteries and
veins.
Conclusion:
Vessel-depleted neck is not a contraindication to
microvascular reconstruction. The branches of external carotid
artery and internal or external jugular veins can be successfully
utilised if present. However, when these are absent, superficial
temporal vessels, transverse cervical and suprascapular arteries
and smaller innominate veins are reliable alternatives. Vein grafts
should be used freely when needed. They have proved very effec-
tive despite widespread use to lengthen both arteries and veins.