185
were enrolled. Among three skin paddles, distal paddle was used
to reconstruct the inner mucosa defect, and other two large skin
paddles were stacked side by side as kissing pattern for outer mega
cheek defect.
Results:
All patients were male, with a mean age of 48.3 years
(range, 29–61 years). All tumour sizes were T4 stage. The mean
area of intraoral defect was 32.2 cm
2
(range, 24–40 cm
2
) and the
mean area of extraoral defect was 106.34 (range, 85.4–143 cm
2
).
The mean width of outer skin defect was 9.5 cm. All flaps survived
and all donor sites were closed primarily.
Conclusion:
Tripaddled ALT flap stacked as kissing pattern is a
novel and reliable modification on conventional flap design, which
provides customised coverage for extensive and full-thickness
buccal defects whilst minimising donor-site morbidity.
http://dx.doi.org/10.1016/j.ijom.2017.02.632Imaging evaluation of recipient vessel of osteoradionecrosis
of the mandible with vascularised flap reconstruction
X.G. Li
∗
, Y. He, J.J. Jiang, Z.L. Liu, C.Y. Ma, H.H. Zhou,
B.C. Wang
Department of Oral and Maxillofacial–Head and Neck
Oncology, Ninth People’s Hospital, Shanghai Jiao Tong
University School of Medicine, Shanghai Key Laboratory of
Stomatology, Shanghai, China
Objectives:
To investigate colour duplex sonography (CDS) and
computed tomography angiography (CTA) — two types of detec-
tion technology used in the evaluation of recipient vessel of
osteoradionecrosis of the mandible with vascularised flap recon-
struction, to provide guidance for surgeons, and reduce the risk of
flap necrosis.
Methods:
10 patients with osteoradionecrosis underwent surgery
and vascularised flap reconstruction, CDS and CTA technology
were used to detect the affected side of the neck, arteriovenous
were detected before operation, and record the related vascular
examination results, statistical analysis of inspection data. The
results of the operation to be confirmed as the gold standard, the
diagnostic test was designed to investigate the accuracy of CDS
and CTA in the diagnosis.
Results:
10 patients underwent reconstruction with fibula myocu-
taneous flap. CDS and CTA detected external maxillary artery
occlusion in four cases (40%), external jugular vein occlusion in
three cases (30%), and carotid artery stenosis, arterial wall cal-
cification formation in one case; CDS could detect the vessel of
blood dynamic before operation, and recipient area around soft
tissue can be three-dimensional imaging display through CTA.
Conclusion:
CDS and CTA are used for the detection of osteora-
dionecrosis of vascular reconstruction of patients before surgery,
can provide the recipient vessels without absence for surgery,
haemodynamic course and syntopy precise information, can sig-
nificantly reduce the risk of vascular tissue flap reconstruction
failure.
http://dx.doi.org/10.1016/j.ijom.2017.02.633Transfer virtual surgery plan in maxillary defect
reconstruction: navigation surgery or model-guided surgery?
J. Liang
∗
, X.F. Shan, L. Zhang, Z.G. Cai
Peking University School of Stomatology, Beijing, China
Background:
As virtual surgery plan (VSP) becomes an
important method for preoperative design in maxillary defect
reconstruction, the two methods to transfer design from computer
to real-time surgery: the navigation guided surgery and model
guided surgery technique had been frequently used and reported.
Objectives:
To compare the repeatability of different methods in
transferring VSP for maxillary defects reconstruction.
Methods:
21 Patients who received maxillary defect reconstruc-
tion using either navigation and/or model guided surgery to
transfer VSP fromMarch 2012 toDecember 2015were included in
this study, and divided according to the transfer methods adopted:
Group A (
n
= 5, used model-guided surgery solely); Group B
(
n
= 16, used navigation and model guided surgery in combina-
tion). The three-dimensional (3D) deviation in midface area of
preoperative design and postoperative CT scan were compared
using a 3D comparing algorithm, the result of 3D deviation less
than 2 mm was recorded.
Findings:
The postoperative computed tomography showed that
the 3D deviation less than 2 mm on midface area was 91.76%
(86.77–96.68%) in Group A, and 90.56% (83.00–96.012%) in
group B, with no significant differences between two groups.
Conclusion:
There was no significant difference between these
two groups in repeatability, but still needs to be proven by a larger
sample. Model-guided surgery can be used for facilitating the tita-
nium plate/mesh bending, while navigation guided surgery show
the real-time location of the grafts. Surgeons can choose different
methods solely or in combination base on the extent of defect and
reconstruction methods.
http://dx.doi.org/10.1016/j.ijom.2017.02.634Total mandibular titanium prosthesis in a child
S.M. Lima Junior
∗
, F.B.D.J. Boos Lima, T. Colferai,
P.H. de Moraes, S. Borges
Federal University of Minas Gerais, Belo Horizonte, Brazil
Objectives:
The aim of this study was to report a case of a six-
year-old child with the diagnosis of Gorham-Stout syndrome,
presentingwithout the completemandible. The patient was breath-
ing because an acrylic device was projecting the muscles, but is
sustained a local infection.
Methods:
The mandibular reconstruction was planned
using computer-aided design/computer-aided manufacturing
(CAD/CAM) technology. The skull of the patient was used
to design and manufacture the customised total mandibular
prosthesis with two temporomandibular joint fossae. CAD of the
surgical devices used NX 10.0 software (Siemens, Plano, Texas,
United States of America). The authors assumed that this design
would maximise aesthetics, mandibular projection, facial height
and future growth. The virtual designed mandible was submitted
to a topological optimisation and finite element analysis in order
to remove excess material and improve stiffness of the mandible.
Findings:
The final result was a mandible weighing 59 g with
two fossae for articulation and with threaded holes for future