82
Conclusion:
The residual condyle grows after LAP, which can
reduce the gravity of jaw bone deformity.
http://dx.doi.org/10.1016/j.ijom.2017.02.292Intraoperative arthroscopy of temporomandibular joint in
patients with condylar head fracture
D. Hirjak
∗
, M. Beno, V. Machon, B. Galis
Department of Oral and Maxillofacial Surgery, Comenius
University University Hospital Ruzinov, Bratislava, Slovakia
Background:
There is a general understanding that condylar
trauma results in both hard and soft tissue injuries. Plain films and
computed tomography (CT) are standard for radiographic evalua-
tion of facial bone fractures. The bony elements have historically
been the focus of the diagnosis and treatment. Magnetic resonance
imaging (MRI) can detect both bone and soft tissue pathology.
We have used perioperative arthroscopic evaluation of upper joint
compartment during open surgery in cases with condylar head
fracture.
Methods:
Arthroscopy of upper compartment was performed in
24 patients with dislocated condylar head fractures. We have
evaluated disc position, disc perforation, cartilage damage, haem-
orrhagic clots, hypervascularity and synovitis. Patients were
divided to two groups, depending on the period from trauma, less
than five days and more than five days.
Results:
In majority of the cases the disc was dislocated anterome-
dially following fragment dislocation. We have had no case with
disc perforation or disc rupture. Hyperemia, haemorrhagic clots
and cartilage erosions were the most frequent changes.
Conclusions:
Information from this study is useful in further-
ing the understanding of intraarticular damage occurring in acute
trauma. Presence of haematoma after acute joint trauma and its
evacuation and early movement may prevent later pathology.
http://dx.doi.org/10.1016/j.ijom.2017.02.293Planes of reference for orbital fractures: computed
tomographic assessment of orbital fractures made easy
J. Hung
∗
, E.Z. Cai, L.S.F. Chan, X.T. Chong, W.L. Ong,
J.Y. Goh, E.C.H. Hing, W.K. Leow, Y.H. Chan, H.J. Lee,
V. Nallathamby, Y.L. Yap, W.C. Ong, J. Lim, S. Gangadhara,
T.C. Lim
Division of Plastic, Reconstructive and Aesthetic Surgery,
Department of Surgery, National University Health System,
Singapore
Background:
The posterior ledge (PL) is the portion of the orbital
floor left after a fracture. It is important for implant placement
during orbital reconstruction. Correct placement involves resting
its posterior aspect on PL. Without knowledge of its location,
dissection to PL is challenging. Inaccurate placement leads to post-
operative complications. We developed a novel technique (Planes
of Reference for Orbital Fractures [PROF]) to determine the most
common location of PL from infraorbital margin (IM).
Methods:
This retrospective study evaluates 104 consecutive
patients with unilateral orbital floor fractures who underwent
orbital floor reconstruction from 2008 to 2013. Of 104 cases, 52
had intact IM and 52 had fractured IM. We excluded patients with
pre-existing orbital pathologies. Facial computed tomography
(CT) scans were analysed using Osirix
®
Lite Digital Imaging and
Communications in Medicine (DICOM) Viewer v7.0.1 (Geneva,
Switzerland). The skull was positioned upright according to the
Frankfurt and midsagittal planes. Measurements were taken on the
sagittal view corresponding to the midorbital line (MOL) bisecting
the fractured orbit. Without intact IM, MOL of the nonfractured
orbit was reflected and superimposed onto the fractured orbit. The
location of PL is determined from the reflected intact IM.
Results:
Orbits with intact IM, PL were located 15.0 mm to
25.0 mm from IM (mean, 22.1 mm; 95% CI, 21.2–23.0 mm).
Fractured IM, PL located 15.0 mm to 25.0 mm from IM (mean,
21.1 mm; 95% CI, 20.2–21.9 mm).
Conclusion:
PROF is an efficient technique in locating PL,
avoiding insufficient or overaggressive dissections during orbital
reconstructions. The mean distance of PL from IM is 22.1 mm and
21.1 mm for intact and fractured IM, respectively.
http://dx.doi.org/10.1016/j.ijom.2017.02.294Comparison of titanium mesh versus
polycaprolactone-tricalcium phosphate implant in orbital
fracture reconstruction
J. Hung
∗
, A.C. Han, E. Cai, L.T. Chye
Division of Plastic, Reconstructive and Aesthetic Surgery,
National University Health Systems, Singapore
Background:
Controversy exists regarding the choice of implant
material for orbital floor reconstructions. This study aims to
compare the effectiveness of titaniummesh and polycaprolactone-
tricalcium phosphate (PCL/TCP) implant for repairing traumatic
orbital fractures.
Methods:
A total of 19 patients with orbital floor reconstructions
operated at the National University Health System, Singapore
were included in this prospective study between November 2010
and June 2013. Titanium mesh was used in 10 patients, while
PCL/TCP implant was used in the other nine patients. Patients
were evaluated for the worsening of visual acuity, presence or
absence of infraorbital nerve paraesthesia, extraocular muscle
function, enophthalmos and diplopia. Postoperative complications
such as infection, early resorption, extrusion and persistent pain
were also recorded.
Results:
Restoration of orbital wall continuity was successful in
all patients. Follow-up duration was at least one year. There was
no statistically significant difference in worsening of visual acuity,
presence or absence of infraorbital nerve paraesthesia, extraocu-
lar muscle function and enophthalmos. Even though there was
no statistically significant difference in diplopia between the two
treatment groups preoperatively, there were more patients who
had diplopia following titanium mesh postoperatively (
P
< 0.05).
One patient had persistent diplopia, enopthalmos and lateral rectus
muscle dysfunction postoperatively, but declined further correc-
tive surgery. There was no infection, early resorption, extrusion or
persistent pain.
Conclusions:
Both groups showed satisfactory results. PCL/TCP
composite can be used to fabricate biodegradable fixators for the
reconstruction of orbital wall fractures.
http://dx.doi.org/10.1016/j.ijom.2017.02.295




