82

Conclusion:

The residual condyle grows after LAP, which can

reduce the gravity of jaw bone deformity.

http://dx.doi.org/10.1016/j.ijom.2017.02.292

Intraoperative arthroscopy of temporomandibular joint in

patients with condylar head fracture

D. Hirjak

∗

, M. Beno, V. Machon, B. Galis

Department of Oral and Maxillofacial Surgery, Comenius

University University Hospital Ruzinov, Bratislava, Slovakia

Background:

There is a general understanding that condylar

trauma results in both hard and soft tissue injuries. Plain films and

computed tomography (CT) are standard for radiographic evalua-

tion of facial bone fractures. The bony elements have historically

been the focus of the diagnosis and treatment. Magnetic resonance

imaging (MRI) can detect both bone and soft tissue pathology.

We have used perioperative arthroscopic evaluation of upper joint

compartment during open surgery in cases with condylar head

fracture.

Methods:

Arthroscopy of upper compartment was performed in

24 patients with dislocated condylar head fractures. We have

evaluated disc position, disc perforation, cartilage damage, haem-

orrhagic clots, hypervascularity and synovitis. Patients were

divided to two groups, depending on the period from trauma, less

than five days and more than five days.

Results:

In majority of the cases the disc was dislocated anterome-

dially following fragment dislocation. We have had no case with

disc perforation or disc rupture. Hyperemia, haemorrhagic clots

and cartilage erosions were the most frequent changes.

Conclusions:

Information from this study is useful in further-

ing the understanding of intraarticular damage occurring in acute

trauma. Presence of haematoma after acute joint trauma and its

evacuation and early movement may prevent later pathology.

http://dx.doi.org/10.1016/j.ijom.2017.02.293

Planes of reference for orbital fractures: computed

tomographic assessment of orbital fractures made easy

J. Hung

∗

, E.Z. Cai, L.S.F. Chan, X.T. Chong, W.L. Ong,

J.Y. Goh, E.C.H. Hing, W.K. Leow, Y.H. Chan, H.J. Lee,

V. Nallathamby, Y.L. Yap, W.C. Ong, J. Lim, S. Gangadhara,

T.C. Lim

Division of Plastic, Reconstructive and Aesthetic Surgery,

Department of Surgery, National University Health System,

Singapore

Background:

The posterior ledge (PL) is the portion of the orbital

floor left after a fracture. It is important for implant placement

during orbital reconstruction. Correct placement involves resting

its posterior aspect on PL. Without knowledge of its location,

dissection to PL is challenging. Inaccurate placement leads to post-

operative complications. We developed a novel technique (Planes

of Reference for Orbital Fractures [PROF]) to determine the most

common location of PL from infraorbital margin (IM).

Methods:

This retrospective study evaluates 104 consecutive

patients with unilateral orbital floor fractures who underwent

orbital floor reconstruction from 2008 to 2013. Of 104 cases, 52

had intact IM and 52 had fractured IM. We excluded patients with

pre-existing orbital pathologies. Facial computed tomography

(CT) scans were analysed using Osirix

®

Lite Digital Imaging and

Communications in Medicine (DICOM) Viewer v7.0.1 (Geneva,

Switzerland). The skull was positioned upright according to the

Frankfurt and midsagittal planes. Measurements were taken on the

sagittal view corresponding to the midorbital line (MOL) bisecting

the fractured orbit. Without intact IM, MOL of the nonfractured

orbit was reflected and superimposed onto the fractured orbit. The

location of PL is determined from the reflected intact IM.

Results:

Orbits with intact IM, PL were located 15.0 mm to

25.0 mm from IM (mean, 22.1 mm; 95% CI, 21.2–23.0 mm).

Fractured IM, PL located 15.0 mm to 25.0 mm from IM (mean,

21.1 mm; 95% CI, 20.2–21.9 mm).

Conclusion:

PROF is an efficient technique in locating PL,

avoiding insufficient or overaggressive dissections during orbital

reconstructions. The mean distance of PL from IM is 22.1 mm and

21.1 mm for intact and fractured IM, respectively.

http://dx.doi.org/10.1016/j.ijom.2017.02.294

Comparison of titanium mesh versus

polycaprolactone-tricalcium phosphate implant in orbital

fracture reconstruction

J. Hung

∗

, A.C. Han, E. Cai, L.T. Chye

Division of Plastic, Reconstructive and Aesthetic Surgery,

National University Health Systems, Singapore

Background:

Controversy exists regarding the choice of implant

material for orbital floor reconstructions. This study aims to

compare the effectiveness of titaniummesh and polycaprolactone-

tricalcium phosphate (PCL/TCP) implant for repairing traumatic

orbital fractures.

Methods:

A total of 19 patients with orbital floor reconstructions

operated at the National University Health System, Singapore

were included in this prospective study between November 2010

and June 2013. Titanium mesh was used in 10 patients, while

PCL/TCP implant was used in the other nine patients. Patients

were evaluated for the worsening of visual acuity, presence or

absence of infraorbital nerve paraesthesia, extraocular muscle

function, enophthalmos and diplopia. Postoperative complications

such as infection, early resorption, extrusion and persistent pain

were also recorded.

Results:

Restoration of orbital wall continuity was successful in

all patients. Follow-up duration was at least one year. There was

no statistically significant difference in worsening of visual acuity,

presence or absence of infraorbital nerve paraesthesia, extraocu-

lar muscle function and enophthalmos. Even though there was

no statistically significant difference in diplopia between the two

treatment groups preoperatively, there were more patients who

had diplopia following titanium mesh postoperatively (

P

< 0.05).

One patient had persistent diplopia, enopthalmos and lateral rectus

muscle dysfunction postoperatively, but declined further correc-

tive surgery. There was no infection, early resorption, extrusion or

persistent pain.

Conclusions:

Both groups showed satisfactory results. PCL/TCP

composite can be used to fabricate biodegradable fixators for the

reconstruction of orbital wall fractures.

http://dx.doi.org/10.1016/j.ijom.2017.02.295