http://dx.doi.org/10.1016/j.ijom.2017.02.305

The precise orientation of preformed titanium plates in

digital surgery technology assisted in reconstruction

operations of mandibular segmental defects

Y. Liang

∗

, W.J. Wang, C.H. Jiang, J. Chen, Y.G. Liu

Xiangya Hospital, Central South University, Changsha, China

Objective:

To explore the precisemethod of orientating preformed

titanium plates in digital surgery technology assisted in the recon-

struction operations of mandibular segmental defects.

Methods:

Seven cases of segmental resections in mandibles

with simultaneous free fibula flap reconstructions from oral

and maxillofacial surgery in Xiangya Hospital were selected,

using cone-beam computed tomography (CBCT) and CT scan-

ning mandibles and fibulas to collect data respectively. Expected

mandibular models were printed after surgical simulations. Tita-

nium plates were preformed for expected mandibular models.

CBCT used to scan the sample to obtain composite models com-

posed of titanium plates and expected models. Finally, designing

the osteotomy guide plates with location holes. Osteotomy guide

plates were emplaced during operation, resecting mandibular

lesions after being drilled and fixed, and emplacing preformed

titanium plates by existed holes. CBCT reconstruction models

were checked after operation, analysing the absolute deviation

of special, and describing deviation by percentiles in the collected

statistics.

Findings:

Seven cases with preformed titanium plates were

emplaced reliably, obtained good recovery in occlusal relationship

and were satisfied with the contour of reconstructed mandibles.

The absolute deviation of postoperative reconstructed mandibles

compared with expected operative models were: P25 = 0.26 mm,

P75 = 1.17 mm; the absolute deviation of titanium plates were:

P25 = 0.08 mm, P75 = 0.43 mm.

Conclusion:

The position relationship between preformed tita-

nium plates and mandibles could be obtained by CBCT scanning

the composite models composed of preformed titanium plates and

expected mandibular models, and the osteotomy guide plates with

location holes could meet the demands for orientating titanium

plates in clinical operations, which deserve the clinical expansion.

http://dx.doi.org/10.1016/j.ijom.2017.02.306

Do we need routiner postoperative radiographic assessment

in orbital repair?

O. Lieger

∗

, F. Schlittler

Department of Cranio-Maxillofacial Surgery, Inselspital, Bern

University Hospital, University of Bern, Switzerland

Objective:

The purpose of this study was to retrospectively assess

the incidence of implant malposition and revision surgeries in

orbital repair in a large trauma centre, where postoperative com-

puted tomography (CT) assessments are performed routinely.

Methods:

This observational study was conducted at the Depart-

ment of Cranio-Maxillofacial Surgery at the University Hospital

of Bern, Switzerland. 71 adult patients were treated with a tita-

nium mesh between September 2008 and December 2015. The

primary indication for surgical repair was the presence of an

isolated or combined orbital fracture causing a functional or aes-

thetical deficit. Exclusion criteria included missing postoperative

follow-up documentation and/or CT scans. Preoperative CT scans

were obtained to assess the size and location of the fracture. To

evaluate accuracy in reconstruction, postoperative CT scans were

performed routinely and the results were classified.

Findings:

A total of 71 patients with 73 implants were included

in this study (49 male, mean age 56). The mean defect size was

2.81. Twelve patients (17%) were confronted with an unsuccessful

treatment outcome and needed revision intervention. Themain risk

factor for revision was a poor postoperative outcome assessment

according to Ellis (

P

< 0.001).

Conclusions:

Patients with extensive orbital defects who require

surgical treatment with a titaniummesh are at high risk for implant

malposition. Since an insufficient position of the implant is the

main reason for a surgical revision, we postulate that a post-

operative radiographic control should be done routinely. Only

then long-term sequel due to inappropriate reconstruction can be

avoided.

http://dx.doi.org/10.1016/j.ijom.2017.02.307

Patients perception of good occlusion and functional

rehabilitation following open reduction and internal fixation

of fractured mandible

R. Madattigowda

∗

, S. Vempaty, M. Perry

Northwick Park Hospital, Harrow, London, United Kingdom

Background:

Open reduction and internal fixation of the frac-

tured mandible is a common procedure undertaken in Oral and

Maxillofacial surgical specialty. In our unit over 200 of them were

performed over a year. Objective assessment of occlusion on the

table while the patient was under general anaesthesia is the usual

practice. It is not possible to get patients feedback about their pro-

prioception of occlusion when the teeth were put together before

the fixation.

Objective:

To evaluate the patient’s perception of their occlusion

and functional satisfaction following fixation.

Methods:

A retrospective study of postsurgical occlusal and func-

tional satisfaction among this patient group was done over the

telephone. The survey was undertaken using a template question-

naire focussing on 1) perception of bite (occlusion), 2) mouth

opening and 3) chewing ability. All the patients in the study were

six months postsurgery.

Findings andConclusion:

In our study all our patients were under

general anaesthesia one has to relay on objective assessment of

occlusion by surgeons. Majority of our patients have reported sat-

isfied with the achieved occlusion by the surgeons. They have

achieved normal functional ability to their satisfaction following

the fixation. However, those who had hypodontia prior to surgery

and those who had extractions at the time of surgery reported to

have low level of satisfaction.