86
http://dx.doi.org/10.1016/j.ijom.2017.02.305The precise orientation of preformed titanium plates in
digital surgery technology assisted in reconstruction
operations of mandibular segmental defects
Y. Liang
∗
, W.J. Wang, C.H. Jiang, J. Chen, Y.G. Liu
Xiangya Hospital, Central South University, Changsha, China
Objective:
To explore the precisemethod of orientating preformed
titanium plates in digital surgery technology assisted in the recon-
struction operations of mandibular segmental defects.
Methods:
Seven cases of segmental resections in mandibles
with simultaneous free fibula flap reconstructions from oral
and maxillofacial surgery in Xiangya Hospital were selected,
using cone-beam computed tomography (CBCT) and CT scan-
ning mandibles and fibulas to collect data respectively. Expected
mandibular models were printed after surgical simulations. Tita-
nium plates were preformed for expected mandibular models.
CBCT used to scan the sample to obtain composite models com-
posed of titanium plates and expected models. Finally, designing
the osteotomy guide plates with location holes. Osteotomy guide
plates were emplaced during operation, resecting mandibular
lesions after being drilled and fixed, and emplacing preformed
titanium plates by existed holes. CBCT reconstruction models
were checked after operation, analysing the absolute deviation
of special, and describing deviation by percentiles in the collected
statistics.
Findings:
Seven cases with preformed titanium plates were
emplaced reliably, obtained good recovery in occlusal relationship
and were satisfied with the contour of reconstructed mandibles.
The absolute deviation of postoperative reconstructed mandibles
compared with expected operative models were: P25 = 0.26 mm,
P75 = 1.17 mm; the absolute deviation of titanium plates were:
P25 = 0.08 mm, P75 = 0.43 mm.
Conclusion:
The position relationship between preformed tita-
nium plates and mandibles could be obtained by CBCT scanning
the composite models composed of preformed titanium plates and
expected mandibular models, and the osteotomy guide plates with
location holes could meet the demands for orientating titanium
plates in clinical operations, which deserve the clinical expansion.
http://dx.doi.org/10.1016/j.ijom.2017.02.306Do we need routiner postoperative radiographic assessment
in orbital repair?
O. Lieger
∗
, F. Schlittler
Department of Cranio-Maxillofacial Surgery, Inselspital, Bern
University Hospital, University of Bern, Switzerland
Objective:
The purpose of this study was to retrospectively assess
the incidence of implant malposition and revision surgeries in
orbital repair in a large trauma centre, where postoperative com-
puted tomography (CT) assessments are performed routinely.
Methods:
This observational study was conducted at the Depart-
ment of Cranio-Maxillofacial Surgery at the University Hospital
of Bern, Switzerland. 71 adult patients were treated with a tita-
nium mesh between September 2008 and December 2015. The
primary indication for surgical repair was the presence of an
isolated or combined orbital fracture causing a functional or aes-
thetical deficit. Exclusion criteria included missing postoperative
follow-up documentation and/or CT scans. Preoperative CT scans
were obtained to assess the size and location of the fracture. To
evaluate accuracy in reconstruction, postoperative CT scans were
performed routinely and the results were classified.
Findings:
A total of 71 patients with 73 implants were included
in this study (49 male, mean age 56). The mean defect size was
2.81. Twelve patients (17%) were confronted with an unsuccessful
treatment outcome and needed revision intervention. Themain risk
factor for revision was a poor postoperative outcome assessment
according to Ellis (
P
< 0.001).
Conclusions:
Patients with extensive orbital defects who require
surgical treatment with a titaniummesh are at high risk for implant
malposition. Since an insufficient position of the implant is the
main reason for a surgical revision, we postulate that a post-
operative radiographic control should be done routinely. Only
then long-term sequel due to inappropriate reconstruction can be
avoided.
http://dx.doi.org/10.1016/j.ijom.2017.02.307Patients perception of good occlusion and functional
rehabilitation following open reduction and internal fixation
of fractured mandible
R. Madattigowda
∗
, S. Vempaty, M. Perry
Northwick Park Hospital, Harrow, London, United Kingdom
Background:
Open reduction and internal fixation of the frac-
tured mandible is a common procedure undertaken in Oral and
Maxillofacial surgical specialty. In our unit over 200 of them were
performed over a year. Objective assessment of occlusion on the
table while the patient was under general anaesthesia is the usual
practice. It is not possible to get patients feedback about their pro-
prioception of occlusion when the teeth were put together before
the fixation.
Objective:
To evaluate the patient’s perception of their occlusion
and functional satisfaction following fixation.
Methods:
A retrospective study of postsurgical occlusal and func-
tional satisfaction among this patient group was done over the
telephone. The survey was undertaken using a template question-
naire focussing on 1) perception of bite (occlusion), 2) mouth
opening and 3) chewing ability. All the patients in the study were
six months postsurgery.
Findings andConclusion:
In our study all our patients were under
general anaesthesia one has to relay on objective assessment of
occlusion by surgeons. Majority of our patients have reported sat-
isfied with the achieved occlusion by the surgeons. They have
achieved normal functional ability to their satisfaction following
the fixation. However, those who had hypodontia prior to surgery
and those who had extractions at the time of surgery reported to
have low level of satisfaction.
http://dx.doi.org/10.1016/j.ijom.2017.02.308