Table of Contents Table of Contents
Previous Page  218 / 398 Next Page
Information
Show Menu
Previous Page 218 / 398 Next Page
Page Background

213

Beta-tricalcium phosphate with adjuvant bone-marrow stem

cells for bone regeneration in calvarial defects: an

in vivo

microcomputed tomographic and histologic experiment in

rats

S. Ramalingam

∗

, N. Nooh, K. Al-Hezaimi

College of Dentistry, King Saud University, Riyadh, Saudi

Arabia

Background:

Alloplastic biomaterials have been used for regen-

eration and reconstruction of osseous defects. The role of adjuvant

bone-marrow mesenchymal stem cells (BMSC) in bone regener-

ation is still unclear.

Objectives:

The objective of the present

in vivo

study was to

assess bone regeneration in standardised rat calvarial defects using

beta-tricalcium phosphate ( -TCP) with adjuvant BMSC.

Methods:

A single full-thickness standardised calvarial defect

(4.6 mm diameter) was created on the left parietal bone in female

Wistar rats (

n

= 40) weighing approximately 300 g and aged about

12 weeks. The animals were randomly divided into four groups

based on the biomaterial used to fill the defect: (1) control group

(

n

= 10); (2) -TCP group (

n

= 10); (3) BMSC group (

n

= 10); (4)

-TCP + BMSC group (

n

= 10). Real-time

in vivo

microcomputed

tomography analyses were performed immediately postsurgery

and at 2, 4, 6 and 10 weeks to determine volume and mineral

density of newly formed bone (BVNFB, MDNFB) and remaining

-TCP particles (VRBP, MDRBP). At 10 weeks the animals were

sacrificed and calvarial specimens were evaluated histologically.

Findings and Conclusion:

Statistically significant increase in

BVNFB and MDNFB were observed as early as 2 weeks, in the

-TCP + BMSC group in comparison to other groups. Histologic

findings at 10 weeks revealed greatest amount of new bone with

abundant osteoblasts, in the -TCP + BMSC group. Based on this

study, significant volumes of new bone with high mineral density

is formed as early as two weeks following bone regeneration with

-TCP + BMSC in rat calvarial defects.

http://dx.doi.org/10.1016/j.ijom.2017.02.722

Average mandibular dimensions of Malaysian population: a

step towards virtual reconstruction of neomandible

S. Raman

∗

, Z. Rahman

Department of Oro-maxillofacial Surgical and Medical

Sciences, Faculty of Dentistry, University of Malaya, Kuala

Lumpur, Malaysia

Background:

The mandible is a very important structure in the

facial region and is involved in several crucial functions and con-

tributes to aesthetics of the face. Unfortunately, it can be affected

by several problems, resulting in alteration of its morphology and

function.

Objectives:

The present study was undertaken to determine mean

values of mandibular linear and angular measurements according

to gender, ethnicity and age and to determine presence of differ-

ence between the right and left side within gender to ensure that

the mandible is returned to its desired shape and form.

Methods:

Linear and angular measurements of mandible were

carried out virtually using Computer-Aided Design software

(SolidWorks Premium 2012) on 150 patients, ranging from 21

to 70 years old with equal gender, ethnic and age group distribu-

tion. Statistical analysis was performed and level of significance

was set at

P

= 0.05.

Findings:

The mean values for linear measurements were higher

in males but females had higher angular measurements. Mean

values were generally lowest for Indians among the ethnic groups.

Most of the linear measurements showed a slight downtrend with

age. The gonial angles demonstrated an increase with age. The

body height of mandible showed a significant difference between

the right and left sides for both themales and females. Both genders

also exhibited significant difference between the right and left

gonial angles.

Conclusion:

Mandibular dimension in Malaysian population

differs between the genders, race and age. Therefore, the recon-

structed dimensions have to be patient-specific to ensure optimum

shape, form and function.

http://dx.doi.org/10.1016/j.ijom.2017.02.723

Evaluation of accuracy of a novel elastic fusion algorithm —

a prospective clinical study

A. Rashad

∗

, P. Hiepe, D. Modrow, J. Keuchel, C. Rendenbach,

M. Heiland, A. Al-Dam

Department of Oral and Maxillofacial Surgery, University

Medical Center Hamburg-Eppendorf, Hamburg, Germany

Background:

Although rigid fusion is generally accepted as gold-

standard method, it often stands for time consuming and manual

registration procedure. A novel elastic fusion algorithm is intro-

duced to overcome these drawbacks.

Objectives:

To investigate image registration accuracy of bony

structures and adjacent soft tissues provided by novel elastic fusion

algorithm.

Methods:

Five patients (3 male, 2 female, mean of 57 years)

with outboard obtained computed tomography (CT) imaging of

the head and neck were included in the study. For each, a 3-Tesla

(3 T) magnetic resonance imaging (MRI; Philips Healthcare, Best,

The Netherlands) of the same region was conducted. The MRI

protocol included three-dimensional (3D), axial and sagittal two-

dimensional scans showing different contrasts and was repeated

three times with the patient in neutral, flexed and rotated head

position. To verify accuracy of novel spine curvature correction

method (embedded in the ImageFusion Element, Brainlab AG,

Feldkirchen, Germany), 80–120 bony landmarks were defined in

the CT image, transferred via rigid fusion and used as starting value

for elastic fusion algorithm. Finally, Euclidian distances between

rigidly and elastically transferred landmarks were determined.

Findings:

Although the image data revealed strong translational

and rotational displacements of vertebrae in both modalities (due

to varying head positions), 95% of the landmarks showed an error

below 3 mm. However, using 3D MRI data provides highest reg-

istration accuracy and co-registration of axial MRI acquisitions is

superior than compared to sagittal MR images.

Conclusion:

Generally, it can be stated that elastic fusion pro-

vides high MR-to-CT image registration accuracy and represents

a considerable step towards soft tissue registration and navigation.

http://dx.doi.org/10.1016/j.ijom.2017.02.724