218
an earlier stage when compared to the conventional method. The
resulting 3D computer model (Catia) was used for 3D printing of a
gypsum mold (Z250 3D Systems Z-corp) and the nylon construct
(EOS Formiga P110, Oceanz) that is integrated to improve collar
stiffness. The mould was used to fabricate a silicon inlay. Due to
the improved fit of the neck collar, patient adherence to wear the
collar was greatly improved when compared to the gypsummould
approach.
Conclusions:
Our approach resulted in early implementation of
neck collar treatment of hypertrophic neck scars. Moreover, the
personalised manufacturing approach improved patient adherence
to wear the collar on a daily base. Our findings suggest that per-
sonalised manufacturing of neck collars could augment therapy in
patients with hypertrophic burn scars.
http://dx.doi.org/10.1016/j.ijom.2017.02.737In vivo
evaluation of microporous silk sponges with modified
pulp for bone tissue engineering
T. Thai
∗
, T. Nuntanaranont, S. Kamolmatyakul, J. Meesane
Prince of Songkla University, Songkhla, Thailand
Background:
Bone resorption following tooth extraction inter-
feres dental implant replacement. Alveolar bone augmentation
routinely facilitate to replace dental implant in a desired position
. 1Objective:
To evaluate bone formation improved by microporous
silk sponges with modified pulp (MS-MP) in animal experiments
for alveolar bone augmentation.
Methods:
The microporous silk sponges (MS) were fabricated
then coated with modified pulp. The 18 bi-circular defects in
rabbit calvaria were used for experiments. They were divided
in two groups randomly: MS-MP and MS. They were sacrificed
at two, four, eight weeks postoperatively. The scanning electron
microscopy, clinical healing, microcomputed tomography, histol-
ogy were used to evaluate the sponges and their bone formation
In vivo
.
Findings:
The MS-MP were fabricated in proper pore size and
highly internal connective porosity for bone regeneration. All
rabbits were good healing without any infection. MS-MP group
enhanced more new bone and thicker than MS group. The forming
bone of MS-MP group was mature faster than MS group.
Conclusion:
The MS-MP showed good biocompatible and osteo-
conductive properties in animal experiments. The MS-MP may a
novel biomaterial for alveolar bone augmentation.
Reference
Jensen, S. S., & Terheyden, H. (2009). Bone augmentation procedures in
localised defects in the alveolar ridge: clinical results with different bone
grafts and bone-substitute materials.
Int J Oral Maxillofac Implants
,
24
,
218–236.
http://dx.doi.org/10.1016/j.ijom.2017.02.738Correction of facial deformity with bespoke patient-specific
polyetheretherketone implant: in-house manufacturing to
virtual planning and navigational technology
M. Thomas
∗
, C. Frezzini, R. Keat, N. Lee
Sheffield Teaching Hospitals NHS Trust, Sheffield, United
Kingdom
Background:
Polyetheretherketone (PEEK) is a semi-crystalline
linear aromatic polymer with properties that makes it a suit-
able material for craniofacial reconstruction. PEEK is versatile
and is an alternative to the current implantable material available
for craniofacial reconstruction. The advances in computer-aided
design/computer-aided manufacturing (CAD/CAM) technology
have made the implants accurate and reproducible.
Objectives:
Case series to take you through the journey frommak-
ing the PEEK implants in-house to using navigational technology.
Methods:
21 patients underwent reconstruction of facial defor-
mity between 2012 and 2015 (19 were posttraumatic and 3 were
congenital defects. Age ranged from 17 to 50 years.
Results:
We performed 22 reconstructions (11 zygomatic, 8
orbital and 1 mandibular), of which 7 were manufactured with
in-house techniques and 15 were manufactured using CAD/CAM
technology. Navigation technology was used for placement of
five orbital implants. Two implants manufactured using in-house
technique required removal.
Conclusions:
PEEK is a versatile material for craniofacial recon-
struction. The in-house technique manufacturing technique had
multiple steps and the needed adjustments for an accurate fit.
The use of CAD/CAM for patient specific implants and use
of navigation has given us accurate reproducible results. The
multisegmented interlocking plates provided added advantage of
additional stability with minimal fixation and ease of insertion.
http://dx.doi.org/10.1016/j.ijom.2017.02.739In vitro
indirect responses of osteoblasts to
polycaprolactone-ceramics scaffolds
N. Thuaksuban
∗
, T. Luntheng, N. Monmaturapoj
Department of Oral and Maxillofacial Surgery, Faculty of
Dentistry, Prince of Songkla University, Hatyai, Songkhla,
Thailand
Background:
Polycaprolactone (PCL)-ceramics scaffolds are
successfully fabricated using melt stretching and compression
molding (MSCM) technique. It processing allows any surgeon
to instantly build three-dimensional scaffolds on the chair side of
surgical operations.
Objectives:
To evaluate effects of calcium and phosphate ions
released from the scaffolds on osteoblast cells.
Methods:
The groups of scaffolds included A; PCL-20% biphasic
calcium phosphate (BCP) (%wt), B; PCL-30%BCP, C; PCL-20%
tricalciumphosphate (TCP) andD; PCL-30%TCP. Indirect effects
of calcium and phosphate ions released from those scaffolds on
proliferation and differentiation ofMC3T3-E1 osteoblast cell lines
were assessed using enzyme-linked immunosorbent assay and
mineralised matrix Alizarin red staining (AR) over 21 days.
Findings:
The cell proliferation in all groups decreased on day
7 relating to the maximum releasing of phosphate ion, whilst, an
increase of proliferation thereafter would relate to the releasing




