209

in various induction media. Flow cytometry was used to iden-

tify MSCs surface markers in additional cell samples, and reverse

transcriptase-polymerase chain reaction was used to determine

gene expression patterns within isolated cells.

Findings and Conclusion:

High numbers of CFUs were

observed, indicating cell self-renewal. Biochemical assays showed

significantly higher alkaline phosphatase activity, lipid droplets

concentration, and glycosaminoglycans levels in cells cultured

in osteogenic, adipogenic, and chondrogenic induction medium,

respectively.

Approximately 1% of the total cell population demonstrated

the capability to differentiate into all 3 mesenchymal lineages.

Chondrogenic gene levels within TMJD-derived cells were sig-

nificantly reduced in passaged culture.

Our results support the hypothesis that MSCs populate the

TMJD and possess proliferation and differentiation capabilities.

These cells may contribute to the regeneration potential of dys-

functional tissue and become the primary component in future

attempts at tissue engineering or regeneration of this complex.

http://dx.doi.org/10.1016/j.ijom.2017.02.709

Neuroprotective and analgesic properties of melatonin:

preliminary results of a randomised, controlled clinical trial

T.Y. Lee

∗

, J.P. Curtin

University of Hong Kong, Hong Kong

Background:

Persisting neurosensory disturbance affects a sig-

nificant number of patients following orthognathic surgery for

which there is currently little to offer. Melatonin has demonstrated

a neuroprotective effect following neural trauma in animal studies.

Hypothesis:

Through its antioxidant properties, melatonin

reduces postoperative pain and diminishes the incidence of neu-

rosensory deficit.

Objectives:

1. To measure the effect of oral melatonin on postoperative pain

perception

2. To determine the impact of oral melatonin on neurosensory

deficits related to orthognathic surgery

3. To measure the impact of oral melatonin on enzymes related

to oxidation pathways

Methods:

A double-blind randomised clinical trial was conducted

and ethics approved. Study groups consisted of a standardised

melatonin dose and identical placebo, commenced the night prior

to surgery, continued for 21 days. All patients underwent surgery

according to standardised protocol. Data collection consisted of

postoperative pain scores, neurosensory testing and biochemical

assays for hydrogen peroxide and antioxidant enzyme levels.

Statistical analysis:

T

-test, correlation, and ANOVA were used.

A

P

value < 0.05 was considered statistically significant.

Findings:

Patients treated with melatonin reported significantly

lower postoperative pain scores, and significantly improved neu-

rosensory profiles up to 1 month postoperation. Biochemically,

significantly lower levels of hydrogen peroxide and higher lev-

els of superoxide dismutase, glutathione peroxidase and catalase

were measured. A statistically significant correlation was found

between pain scores, antioxidant levels and neurosensory testing

profile.

Conclusion:

Significant benefit of melatonin on postoperative

recovery was found, correlating statistically with enzymatic

changes induced by melatonin. These preliminary results sup-

ported our hypothesis and we await further data.

http://dx.doi.org/10.1016/j.ijom.2017.02.710

Three-dimensional printing of patient specific boluses for

radiation therapy

N. Liberton

∗

, S. te Slaa, M. van Eijnatten, J. Wolff,

T. Forouzanfar

Department of Oral and Maxillofacial Surgery/3D Innovation

Lab, VU University Medical Center, Amsterdam, The

Netherlands

Background and Objectives:

Boluses are widely used in radi-

ation therapy to correct for anatomical irregularities and deliver

correct radiation doses to the tumour, especially in patients being

treated for skin cancers and head and neck cancers. Abolus is made

of a flexible material with properties equivalent to tissue when

irradiated. However, most conventional boluses are suboptimal

since they do not conform to patient anatomy. This presentation

will demonstrate how novel three-dimensional (3D) printing tech-

nologies can be used to manufacture patient-specific boluses for

radiation therapy.

Methods:

Computed tomography images of the patient are con-

verted into a patient-specific bolus design using an in-house

developed dose calculation algorithm. This algorithm optimises

the dose distribution with regard to dose coverage, conformity,

and homogeneity within the tumour. The designed bolus is used

to create a mould which is manufactured using an inkjet 3D printer.

In a final step, liquid tissue-equivalent silicon is poured into the

mould which can be removed after the silicon has set.

Findings:

Since 2014, 157 patients have been treated in the

VU University Medical Center using 3D printed patient-specific

boluses. All 3D printed boluses demonstrated an excellent fit,

which resulted in an improved overall accuracy of dose delivery.

Furthermore, the introduction of 3D printing in radiation therapy

has reduced the lead time hence costs of the treatment.

Conclusions:

The combination of the novel dose calculation

algorithm and 3D printing has improved the quality of radiation

therapy. In the near future, direct silicon printing will allow even

faster treatment of cancer patients.

http://dx.doi.org/10.1016/j.ijom.2017.02.711

What is our goal in orbital reconstruction? Quantitative

assessment of orbital volume in 100 individuals by manual

segmentation and automatic registration

O. Lieger

∗

, M. Schaub, E. Taghizadeh, Ph. Büchel

Department of Cranio-Maxillofacial Surgery, Inselspital, Bern

University Hospital, University of Bern, Switzerland

Background and Objectives:

The knowledge on the symmetry

of intra-individual orbital volumes is crucial when applying radio-

logical quantitative assessment methods for preoperative planning

and postoperative outcome evaluation. To generate these values,

the bony orbits in facial computed tomography (CT) scans were

analysed using a manual segmentation and automatic registration.

Methods:

A surface mesh of the surface of orbit of 100 patients

was extracted from CT scans. The average shape of the orbit