161
antenna attached to the silicone pad combination with a custom-
made dental registration splint.
Methods:
The splint was made of an acrylic resin and had an ante-
rior extension using contrast resin; it incorporated a total of five
holes for marker-based pair-point registration. The splint allowed
rigid stability of the patient who required Le Fort I osteotomywhile
cone-beam computed tomography (CBCT) was taken. CBCT data
was used for preoperative planning and intraoperative navigation.
The reference antenna attached to the silicon pad was adapted to
nasion of the patient. The registration process was conducted by
means of the fiducial markers incorporated in the splint.
Results:
There was improvement of navigation accuracy by using
present surgical navigation management. Furthermore, no signif-
icant error and surgical complications were detected.
Conclusion:
Our method for surgical navigation system is a
promising tool aiming to improve the safety and precision of
orthognathic surgery.
http://dx.doi.org/10.1016/j.ijom.2017.02.552Calvarial bone graft in reconstructive rhinoplasties
R. Lamartine Monteiro
∗
, A. Lemaitre, Y. Deniz, C. Aubert,
M. Shahla, Y. Vanhemelrijck, D. Dequanter, P. Lothaire
CHU Charleroi, Belgium
In most cases of rhinoplasty a resection of the nasal osseocarti-
laginous framework is sufficient to achieve aesthetic or functional
objectives. Saddle nose is seen in patients who lose loss struc-
tural integrity with subsequent collapse. Various causes could be
the result of this deformity that include traumatic, congenital,
iatrogenic (secondary to reduction of nasal dorsum, drug abuse,
infection and granulomatous diseases).
When a nasal defect involves all or part of the bony pyramid,
the missing portion of the nasal bone is usually replaced with
autologous bone grafts which are sculpted to the defect and are
secured to the remaining bony and cartilage framework.
Different types of graft materials are used to the reconstruction
of the nasal framework like iliac bone, cranial vault, rib bone and
cartilage, bone bank, synthetic material. Many grafting techniques
have been described for use in primary or revision rhinoplasties.
We reviewed a series of 100 patients using cranial vault as the
preferential bone graft for nasal reconstruction over the past 10
years. A ‘L-shaped’ framework is mostly used and bone grafts are
assembled and fixed using titanium screws.
Cranial bone grafts is an efficient technique for nasal
reconstruction achieving good functional and aesthetics results.
Evaluations were made by radiographic findings and postoperative
photographs.
http://dx.doi.org/10.1016/j.ijom.2017.02.553335
Accuracy of three-dimensional natural head position
recording modalities
M.Y. Leung
∗
, J. Lo, Y.Y. Leung
The University of Hong Kong, Hong Kong
Background:
Three-dimensional (3D) images are acquired
with stabilisation device(s) to minimise image artefacts. These
device(s) positioned the patient’s head into a random orientation.
Reorientation of the 3D images into natural head position (NHP)
is a prerequisite for proper assessment of dentofacial deformities.
Objective:
The objectives were to evaluate the emerging tech-
nologies to record NHP in 3D and to compare their accuracy.
Methods:
A systematic review of the Cochrane Library, PubMed
and Embase database was performed in four rounds. The advan-
tages, limitations and accuracies of the modalities to record NHP
in 3D were compared.
Findings:
Eight articles were included. Six 3D NHP recording
modalities were identified. Digital orientation sensing had good
accuracy, with mean angular differences from the reference of less
than one degree. Laser scanning was shown to have comparable
accuracy. The modality involving clinical photo and pose from
orthography and scaling with iterations (POSIT) algorithm was
also accurate, with less than 1
◦
mean angular differences in pitch,
roll and yaw. Stereophotogrammetry had the highest reliability
with the mean angular deviations in pitch, roll, and yaw within
0.1
◦
.
Conclusion:
Digital orientation sensor and laser scanner were
shown to accurately record NHP in 3D. Routine use of laser
scanner was difficult due to its high cost and bulkiness. Stereopho-
togrammetry and the modality utilising clinical photograph and
POSIT algorithm were possible alternatives.
http://dx.doi.org/10.1016/j.ijom.2017.02.554Distraction osteogenesis of the mandible: does postoperative
infection affect stability?
T.S. Li
∗
, W.S. Choi
The University of Hong Kong, Hong Kong
Background:
Up to the present time, no study has attempted
to explore a possible association between skeletal stability and
postoperative infection in mandibular advancement by distraction
osteogenesis.
Objectives:
To determine any possible association between
postoperative infection and skeletal stability of mandibular
advancement by distraction osteogenesis for the treatment of
Skeletal Class II patients.
Methods:
Retrospective study of 20 Class II patients previously
treated by distraction osteogenesis for mandibular advancement.
Clinical records of these patients were reviewed and lateral
cephalograms were used. Prevalence and duration of postoperative
infection were recorded. Skeletal relapse was calculated based on
serial hand tracings of lateral cephalograms. Statistical analysis
of the data was performed to determine any association between
prevalence and duration of postoperative infection and skeletal
relapse.