158
Variation of plate fixation for mandibular advancement with
intraoral vertical ramus osteotomy using
endoscopically-assisted intraoral rigid or semi-rigid internal
fixation: postoperative condylar seating control for
mandibular advancement
S. Hara
∗
, M. Mitsugi, Y. Tatemoto
Department of Oral and Maxillofacial Surgery, Kochi Health
Sciences Center, Kochi-city, Japan
Background:
We have recently controlled intraoperative condylar
seating, with adjustable holes such plates as a sliding plate or
MOJ plate. However, even when using such plates, postoperative
passive condylar seating cannot be done.
Objectives:
The purpose of the present study was to evaluate the
safety and efficacy associated with mandibular advancement by
intraoral vertical ramus osteotomy (IVRO) with endoscopically-
assisted intraoral rigid or semi-rigid internal fixation.
Methods:
The study sample included all patients who had
undergone a mandibular advancement by IVRO procedure with
endoscopically-assisted intraoral plate fixation from September
2008 to May 2012. A mandibular advancement by IVRO with
endoscopically assisted intraoral rigid or semi-rigid internal fix-
ation was used for mandibular advancement. The patients were
analysed prospectively, with more than two years of follow-up,
and were evaluated in terms of functional results, postoperative
complications, and skeletal stability.
Findings:
A total of 14 patients (bilateral, seven patients with class
II; unilateral, seven patients with asymmetry) were included in the
present study. The average degree of mandibular advancement was
5.5
±
1.9 mm (range, 3–9 mm). Both the occlusal relationship and
facial appearance in all patients were significantly improved by
the surgical-orthodontic treatment, with no major harmful clin-
ical symptoms. In addition, one-screw semi-rigid fixation could
control postoperative passive condylar seating.
Conclusion:
This study showed that mandibular advancement by
IVRO with endoscopically assisted, intraoral semi-rigid internal
fixation offers a promising treatment alternative for patients with
skeletal class II malocclusion or facial asymmetry.
http://dx.doi.org/10.1016/j.ijom.2017.02.543The novel use of customised rapid prototyped osteotomy
template in correction of severe mandibular asymmetry: a
case report
S. Hassan
∗
, K. Kadir, P. Shanmuhasuntharam
Department of Oral and Maxillofacial Clinical Sciences, Faculty
of Dentistry, University of Malaya, Kuala Lumpur
Severe mandibular asymmetry causes both functional and aes-
thetic disturbance in patient. Managing it can be challenging as
the complexity of the bony geometry and other facial structures.
Complications such as undercorrection, overcorrection and injury
to the inferior dental nerve may arise as it is difficult to control the
osteotomy line, shape and amount of osteotomy. Therefore, cor-
rect method should be explored to produce the same osteotomy
designed cut pre- and postoperatively.
In this report, a case of severe mandibular asymmetry
which was corrected by using customised rapid prototyped (RP)
osteotomy template is described. The measurement of the vol-
ume, shape, osteotomy line and distance from inferior dental canal
was established by using computer-aided design (3D Slicer and
Autodesk Meshmixer Software) and further osteotomy cut was
performed using the fabricated osteotomy template. Intraopera-
tively, the template was fitted well to the contour of the mandible.
Postoperative cone-beam computed tomography revealed that
both lower border of mandible has become symmetric and the
results were comparable with preoperative planning. In addition,
inferior dental nerve was preserved and good aesthetic result was
achieved. This report suggested that customised RP osteotomy
template could give better accuracy, efficiency and avoid compli-
cations in guiding osteotomy in mandibular asymmetry.
http://dx.doi.org/10.1016/j.ijom.2017.02.544Accuracy of orthognathic surgery — a retrospective service
evaluation
A. Hills
∗
, K. Gowans, A. DiBiase, J. McKenzie, N. Goodger
East Kent Hospitals University NHS Foundation Trust, United
Kingdom
Background:
2700 orthognathic procedures are carried out in
England per annum. The multidisciplinary nature of treatment and
potential for variations in planning and surgical method means
limited data exists on the accuracy of surgery. Inaccurate surgery
adversely affects length of treatment, inconveniencing patients as
well as detrimentally affecting service provision, finances and allo-
cation of hospital resources. Analysis of surgical accuracy helps
identify areas to address to improve outcomes.
Objectives:
To assess the accuracy of orthognathic surgical pro-
cess, including presurgical orthodontics, presurgical work-up,
laboratory model surgery and surgery itself.
Methods:
Between 1st January and 31st December 2014, 27
patients underwent maxillary osteotomies at East Kent University
Hospital Foundation Trust. A retrospective service evaluation was
performed using pre- and postoperative digital lateral cephalomet-
ric radiographs. These were superimposed by computer software
(Opal, 2010) and a custom analysis used to identify the difference
between the pre- and postoperative maxillary positions. Maxillary
anterior-posterior movement, along with posterior and anterior
impaction were assessed. It was not possible to measure cant or
horizontal movements using this method.
Results:
The mean difference between actual and planned surgical
movement of the maxilla in anterior-posterior, posterior impaction
and anterior impaction movements was 0.57 mm, 0.96 mm and
0.55 mm respectively. No statistical difference was demonstrated
between any of the planned and actual movements (
P
> 0.05).
Conclusion:
Surgical maxillary movements can on average be
achieved within 1 mm of the planned movement, with anterior-
posterior movement being the most accurate. This accuracy is
comparable to similar studies using alternative planning and sur-
gical techniques.
http://dx.doi.org/10.1016/j.ijom.2017.02.545