Table of Contents Table of Contents
Previous Page  163 / 398 Next Page
Information
Show Menu
Previous Page 163 / 398 Next Page
Page Background

158

Variation of plate fixation for mandibular advancement with

intraoral vertical ramus osteotomy using

endoscopically-assisted intraoral rigid or semi-rigid internal

fixation: postoperative condylar seating control for

mandibular advancement

S. Hara

∗

, M. Mitsugi, Y. Tatemoto

Department of Oral and Maxillofacial Surgery, Kochi Health

Sciences Center, Kochi-city, Japan

Background:

We have recently controlled intraoperative condylar

seating, with adjustable holes such plates as a sliding plate or

MOJ plate. However, even when using such plates, postoperative

passive condylar seating cannot be done.

Objectives:

The purpose of the present study was to evaluate the

safety and efficacy associated with mandibular advancement by

intraoral vertical ramus osteotomy (IVRO) with endoscopically-

assisted intraoral rigid or semi-rigid internal fixation.

Methods:

The study sample included all patients who had

undergone a mandibular advancement by IVRO procedure with

endoscopically-assisted intraoral plate fixation from September

2008 to May 2012. A mandibular advancement by IVRO with

endoscopically assisted intraoral rigid or semi-rigid internal fix-

ation was used for mandibular advancement. The patients were

analysed prospectively, with more than two years of follow-up,

and were evaluated in terms of functional results, postoperative

complications, and skeletal stability.

Findings:

A total of 14 patients (bilateral, seven patients with class

II; unilateral, seven patients with asymmetry) were included in the

present study. The average degree of mandibular advancement was

5.5

±

1.9 mm (range, 3–9 mm). Both the occlusal relationship and

facial appearance in all patients were significantly improved by

the surgical-orthodontic treatment, with no major harmful clin-

ical symptoms. In addition, one-screw semi-rigid fixation could

control postoperative passive condylar seating.

Conclusion:

This study showed that mandibular advancement by

IVRO with endoscopically assisted, intraoral semi-rigid internal

fixation offers a promising treatment alternative for patients with

skeletal class II malocclusion or facial asymmetry.

http://dx.doi.org/10.1016/j.ijom.2017.02.543

The novel use of customised rapid prototyped osteotomy

template in correction of severe mandibular asymmetry: a

case report

S. Hassan

∗

, K. Kadir, P. Shanmuhasuntharam

Department of Oral and Maxillofacial Clinical Sciences, Faculty

of Dentistry, University of Malaya, Kuala Lumpur

Severe mandibular asymmetry causes both functional and aes-

thetic disturbance in patient. Managing it can be challenging as

the complexity of the bony geometry and other facial structures.

Complications such as undercorrection, overcorrection and injury

to the inferior dental nerve may arise as it is difficult to control the

osteotomy line, shape and amount of osteotomy. Therefore, cor-

rect method should be explored to produce the same osteotomy

designed cut pre- and postoperatively.

In this report, a case of severe mandibular asymmetry

which was corrected by using customised rapid prototyped (RP)

osteotomy template is described. The measurement of the vol-

ume, shape, osteotomy line and distance from inferior dental canal

was established by using computer-aided design (3D Slicer and

Autodesk Meshmixer Software) and further osteotomy cut was

performed using the fabricated osteotomy template. Intraopera-

tively, the template was fitted well to the contour of the mandible.

Postoperative cone-beam computed tomography revealed that

both lower border of mandible has become symmetric and the

results were comparable with preoperative planning. In addition,

inferior dental nerve was preserved and good aesthetic result was

achieved. This report suggested that customised RP osteotomy

template could give better accuracy, efficiency and avoid compli-

cations in guiding osteotomy in mandibular asymmetry.

http://dx.doi.org/10.1016/j.ijom.2017.02.544

Accuracy of orthognathic surgery — a retrospective service

evaluation

A. Hills

∗

, K. Gowans, A. DiBiase, J. McKenzie, N. Goodger

East Kent Hospitals University NHS Foundation Trust, United

Kingdom

Background:

2700 orthognathic procedures are carried out in

England per annum. The multidisciplinary nature of treatment and

potential for variations in planning and surgical method means

limited data exists on the accuracy of surgery. Inaccurate surgery

adversely affects length of treatment, inconveniencing patients as

well as detrimentally affecting service provision, finances and allo-

cation of hospital resources. Analysis of surgical accuracy helps

identify areas to address to improve outcomes.

Objectives:

To assess the accuracy of orthognathic surgical pro-

cess, including presurgical orthodontics, presurgical work-up,

laboratory model surgery and surgery itself.

Methods:

Between 1st January and 31st December 2014, 27

patients underwent maxillary osteotomies at East Kent University

Hospital Foundation Trust. A retrospective service evaluation was

performed using pre- and postoperative digital lateral cephalomet-

ric radiographs. These were superimposed by computer software

(Opal, 2010) and a custom analysis used to identify the difference

between the pre- and postoperative maxillary positions. Maxillary

anterior-posterior movement, along with posterior and anterior

impaction were assessed. It was not possible to measure cant or

horizontal movements using this method.

Results:

The mean difference between actual and planned surgical

movement of the maxilla in anterior-posterior, posterior impaction

and anterior impaction movements was 0.57 mm, 0.96 mm and

0.55 mm respectively. No statistical difference was demonstrated

between any of the planned and actual movements (

P

> 0.05).

Conclusion:

Surgical maxillary movements can on average be

achieved within 1 mm of the planned movement, with anterior-

posterior movement being the most accurate. This accuracy is

comparable to similar studies using alternative planning and sur-

gical techniques.

http://dx.doi.org/10.1016/j.ijom.2017.02.545