Table of Contents Table of Contents
Previous Page  78 / 398 Next Page
Information
Show Menu
Previous Page 78 / 398 Next Page
Page Background

73

Findings:

Based on the observations from our study type 2a and

type 0 lip patterns in parents of cleft lip and palate affected chil-

dren. ATD angles assymetry provide positive objective criteria for

estimating the relative risk and could be used as genetic markers.

Conclusion:

Noninvasive tools are an effort to take a step forward

in shedding light on the prediction of transmission of cleft lip and

palate deformity to the offspring.

http://dx.doi.org/10.1016/j.ijom.2017.02.262

The reliability of stereoscopic display in assessing dentofacial

deformities

S. Zhu

∗

, B. Khambay, Y. Yang, N. Samman

Faculty of Dentistry, The University of Hong Kong, Hong Kong

Background:

To date no studies have investigated the reliability

of stereoscopic display in dentistry. It has been reported to sig-

nificantly improve diagnosis and treatment planning in medicine

since it could recover “binocular” depth perception as experienced

in human visual system.

Objectives:

To compare stereoscopic projected three-dimensional

(3D) images with routine viewing media i.e. plaster casts, two-

dimensional (2D) images, and 3D images in the evaluation of

dental arch relationships and facial features in patients with dento-

facial deformities.

Methods:

The GOSLON Yardstick was used to assess dental arch

relationships on plaster casts, 3D study models scanned by an

intraoral scanner, and stereoscopic projected 3D study models

in 29 patients with unilateral cleft lip and palate. Specific facial

features (height, symmetry, profile) representing facial spatial con-

figuration were evaluated on 2D, 3D and stereoscopic projected

3D images of forty presurgical skeletal Class III patients using

100 mm visual analogue scales (VAS). Rating panel consisted of

a group of professionals. Rating sessions were repeated once.

Findings:

Intrarater and interrater reliability were all above

“good” except intrarater reliability of assessing facial features.

There was no significant difference when rating facial height using

2D photographs, symmetry using 3D images, and profile using

stereoscopic 3D images. The agreement between plaster casts and

either 3D or stereoscopic 3D study models was “good” to “very

good”.

Conclusion:

Stereoscopic projected 3D could supplant the plaster

casts and conventional 3D when assessing dental arch relation-

ships in cleft patients; however, reliability of rating each specific

feature relied upon the type of viewing media.

http://dx.doi.org/10.1016/j.ijom.2017.02.263

Craniomaxillofacial Trauma

ong-term experience with endoscopic intraoral plating of

orbital floor fractures

M. Abba

∗

, O. Nahlieli, A. Zagury

Barzilai Medical Center, Ashkelon, Israel

Background:

Minimal invasive techniques have an increasing

role in all surgical fields because they result in improved morbid-

ity rates and better aesthetic outcomes. We present a minimally

invasive technique for treating orbital blowout fractures.

Objectives:

This article describes the endoscopic approach for

orbital floor fractures, reduction, and fixation and reports the clin-

ical results of long-term experience of 32 cases.

Methods:

32 patients who sustained either a comminuted or trap

door orbital floor fracture were treated in our medical centre fol-

lowing the same surgical protocol. The indications for orbital

reconstruction were limited eye movement, diplopia, and signifi-

cant enophthalmos. The approach is discussed in detail.

Results:

All patients healed uneventfully, one patient with no res-

olution of diplopia after surgery because of late intervention (two

weeks) and one patient with chronic sinusitis due to anterior antral

wall bony sequester. No major complications were noted in the

postoperative period, and good functional and aesthetic results

were obtained. Prolonged infraorbital paraesthesia was the most

common mild long-term complication.

Conclusions:

Our results presented a high success rate with min-

imal complications thus our technique is a safe way with minimal

morbidity for treating orbital floor fractures.

http://dx.doi.org/10.1016/j.ijom.2017.02.264

Temporomandibular joint response to mandibular

parasymphysis and angle fracture: an overview of risk

factors

A. Akare

∗

, A. Datarkar, P. Pandilwar

Government Dental College and Hospital, Nagpur, India

Background:

Fractures of the mandibular angle account for

23–42% of all facial fractures with a high complication rate

(0–32%). Although the ideal treatment remains debatable, two

main procedures are commonly used to manage the majority of

mandibular angle fractures that are open reduction and internal

fixation by a noncompression miniplate placed on the external

oblique ridge with or without a second miniplate on the outer

cortex.

Objectives:

This study had two objectives: first to define the geo-

metric changes in themandibular condyle and secondly to examine

in a clinical study the temporomandibular joints (TMJ) of 60

patients after treating fractures of to find out if there were any

long-term adverse effects.

Methods:

Total 60 patients were treated and divided into two

groups. Group A patients manage by single miniplate and Group

B patients treated by double miniplate. Group A and B fur-

ther divided into A1, A2 and A3; B1, B2 and B3. A1 and B1

patients with favourable angle and parasymphysis fracture. A2

and B2 favourable angle and unfavourable parasymphysis. A3

and B3 with unfavourable angle and parasymphysis. Patients were

evaluated for malocclusion, interincisal mouth opening, condylar

resorption, height of ramus, condylar pain, condylar remodelling.

All patients were followed up for minimum of 6 months to maxi-

mum of 24 months.

Findings:

Eight patients developed postoperative complications.

A higher rate of complications was found among patients with

Group A2 and A3.

Conclusion:

This study suggests that the use of two miniplates for

the internal fixation of mandibular unfavourable parasymphysis

and angle fracture provided a low rate of complications.

http://dx.doi.org/10.1016/j.ijom.2017.02.265