94
All of the implants survived, with good anchorage and proper soft
tissue healing and were all rehabilitated.
http://dx.doi.org/10.1016/j.ijom.2017.02.333Reconstruction with “tent pole” grafts for severely resorbed
jaws: a case report
Y.C. Chen
∗
, S.C. Lin
Department of Oral and Maxillofacial Surgery, China Medical
University Hospital, Taichung City, Chinese Taipei
In the past, numerous efforts or treatment modalities have been
offered to reconstruct severely resorbed mandibular ridge only to
result in rapid resorption of bone graft associated with soft tissue
contraction and they might even be complicated by jaw fracture,
wound dehiscence, fistulas formation, and neurosensory distur-
bance. With the “soft tissue matrix expansion” and “tent pole”
grafting concepts advocated by Prof. Robert E. Marx, simultane-
ous implantation and bone grafting as 1-stage procedure through
submental approach can be achieved with well consolidation and
volume maintenance of grafted bone and predictable long-term
implant success.
We would like to present a case of a 56-year-old female patient
referred from a local dental clinic for oral rehabilitation using
implant restorations. Clinical examination and cone-beam com-
puted tomography revealed severe atrophy of both maxilla and
mandible. After consultation with prosthodontist, implant sup-
ported overdentures was planned for her including autogenous
iliac J-bone blocks grafting for maxillary arch and simultane-
ous implant placement with “tent pole” grafts for mandibular
arch through submental approach. Surgical wound on both arches
healed uneventfully and subsequent placement (stage-I implanta-
tion) of regular sized dental implants on maxilla and uncovering
(stage-II implantation) of the four mandibular implants was per-
formed at five months after surgery.
http://dx.doi.org/10.1016/j.ijom.2017.02.334Factors affecting the release of titanium into human serum
J. Curtin
∗
, M. Wang, H. Sun
The University of Hong Kong, Hong Kong
Background:
Often cited to be virtually insoluble, clinical studies
confirm the release of titanium into human serum even in the
absence of wear. This paper presents
in vitro
results to explain
this ongoing release titanium from surgical devices in humans,
and improves our understanding of the underlying kinetics of this
process.
Objectives:
1. To review the evidence for the release of titanium ions in human
cells and tissues.
2. To present
in vitro
evidence for the release of titanium ions into
human serum.
3. To investigate the role of transferrin and buffering organic acids
on titanium release.
4. To examine the binding of titanium to transferrin (Ti-Tf) by
X-ray crystallography.
Methods:
1. Systematic review of literature summarising relevant
in vitro
data relating to titanium release
2. Determination of titanium (IV) levels in human serum, and
the effects of citrate, lactate and transferrin on titanium release
after 7 days immersion using ICP
3. X-ray crystallography of the Ti-Tf structure
Findings:
The presence of lactate and citrate greatly enhance
Ti(IV) levles, reflected in a linear logarithmic relationship. This
relationship does not exist with transferrin. Citrate is found to bind
Ti(IV) in the transferrin.
Conclusions:
The release of titanium ions from surgical devices
implanted into the human body may occur under physiological
conditions, and is primarily dependent on the presence of citrate
and lactate. It is likely that binding to transferrin occurs secondar-
ily, in a process coordinated by citrate.
http://dx.doi.org/10.1016/j.ijom.2017.02.335Evaluation of periimplant bone level around implants with
platform-switched abutments inserted using computed
tomography-based software planning and computer-aided
design/computer-aided manufacturing guided surgical
template
S.C. Debnath
∗
, A. Vatsyayan, A.K. Adhyapok
Department of Oral and Maxillofacial Surgery, Regional Dental
College and Hospital, Guwahati, Assam, India
Background:
The maintenance of periimplant bone is a major
factor in the prognosis of prosthetic rehabilitation supported by
implants. In an attempt to improve long-term bone maintenance
around dental implants, a new implant-to abutment connection
referred to as “platform switching” has been proposed
. 1Objectives:
To compare the crestal bone height changes
around dental implants with platform- and nonplatform-switched
abutment inserted using computed tomography-based software
planning and computer-aided design/computer-aided manufactur-
ing (CAD/CAM) guided surgical template.
Methods:
A total of 14 implants were placed and patients were
divided into two groups. Seven implants with a diameter of 4.6 mm
and restored with platform-switched abutments (3.5 mm) served
as the test group. Seven implants with a diameter of 4.6 mm and
restored with a horizontally matching abutment diameter served
as the control group. Standardised digital panoramic images were
obtained for evaluation of marginal bone levels at the time of place-
ments of prosthesis (baseline), 6 and 12 months follow-up. All
implants were placed with CAD/CAM-generated surgical guides
after virtual planning of implant placement.
Findings:
The platform-switched implants exhibited statistically
significant less bone loss at time of insertion of the definitive pros-
thesis (0.93
±
0.10 mm versus 1.40
±
0.26,
P
< 0.05) and at one
year (1.47
±
0.15 versus 2.19
±
0.15 mm,
P
< 0.05) when com-
pared to the nonplatform-switched implants.
Conclusion:
It can be concluded that platform switching is capa-
ble of reducing or eliminating crestal bone loss.
Reference
Lazzara, R. J., & Porter, S. S. (2006). Platform switching: a new concept in
implant dentistry for controlling postrestorative crestal bone levels.
Int
J Periodontics Restorative Dent
,
26
, 9–17.
http://dx.doi.org/10.1016/j.ijom.2017.02.336




