322

by computing the CT data of the structures. The mandibular rota-

tion was broken down into the frontal and the horizontal rotation.

Connection of the two rotational centres was the mandibular rota-

tion axis. The rotational centre was measured from the point where

the midface OSP met the lower chin border (FC) and the frontal

rotational centre distance (FRCD) and the horizontal rotational

centre distance (HRCD) were recorded.

Findings and Conclusion:

Analysis results showed that the rota-

tional axes highly varied in its location. The median FRCD was

126.1 mm (range,

−

195.9 to 2304.1 mm) and the median HRCD

was 153.4 mm (range,

−

110.3 to 2942.7 mm). There was no sig-

nificant difference between the FRCD and HRCD (

P

= 0.855).

Because of the highly variable location of the axes, the mandibular

rotations could hardly be categorised as roll, yaw or a combination

of them, which is defined as rotation around the geographic centre

of the structure. As a result, de-rotation of the mandible would be

difficult without using the OSPs as guides.

http://dx.doi.org/10.1016/j.ijom.2017.02.1084

The application of digital technology for 12 patients in

dentomaxillofacial deformities

W.Y. Chuo

School of Stomatology, Hospital of Stomatology, China Medical

University, China

Objective:

To explore the application of digital technology in the

treatment of dentomaxillofacial deformities.

Methods:

Twelve patients of dentomaxillofacial deformities were

enrolled with three-dimensional (3D) computed tomography of

maxillary and mandible. The dicom date was input into the

software of Proplan CMF. We built a digital skull model and 3D-

printed skull model to perform surgical planning, postoperative

prediction and simulate operation. Clinical examination of facial

symmetry was performed 3 months later.

Results:

All the surgical planning, postoperative predictions and

simulate operations of the twelve patients of dentomaxillofacial

deformities were performed, and the orthognathic surgeries were

successful. The patients were satisfied with the facial symmetry 3

months after operations, with a satisfaction rate of 91.67%.

Conclusion:

Using digital technology to perform surgical plan-

ning and simulate surgery improved the accuracy of surgeries

and resulted in satisfied effect. Therefore, digital technology has

practical value in dentomaxillofacial deformities.

http://dx.doi.org/10.1016/j.ijom.2017.02.1085

Non-grafted sagittal split osteotomy versus grafted sagittal

split osteotomy to reduce mandibular lower border defects in

orthognathic surgery. A cohort study

A. Contreras

∗

, J.O. Adbaje, D. Jerez, N. Yanine, A. Gantz,

A. Barrera, J. Cifuentes, C. Politis

Maxillofacial Surgery Unit, Faculty of Medicine, Clínica

Alemana de Santiago – Universidad del Desarrollo, Santiago,

Chile

Background:

The prevention of mandibular lower border defects

is an important issue to be taken into account after largemandibular

advancement with bilateral sagittal split osteotomy (BSSO).

Objectives:

The aim of this study is to compare the incidence of

mandibular border defects when non-grafted BSSO versus grafted

BSSO are used.

Methods:

The authors undertook a retrospective cohort study

comparing two different sagittal split osteotomies techniques:

Group A: traditional non-grafted BSSO technique and Group B:

traditional grafted BSSO technique. One year after surgery, the

presence or absence of a defect was determined by the use of

panoramic X-rays.

Results:

A total of 600 operation sites in 300 patients were

included in the study (age, sex and mandibular advancement were

similar between the groups

P

> 0.05). The proportion of lower

border mandibular defects of operation sites was: group A 36.5%

and group B 1.5%. Traditional grafted BSSO technique was sub-

stantially superior preventing the incidence of mandibular lower

border defects compared with traditional non-grafted BSSO tech-

nique (

P

< 0.05).

Conclusions:

Mandibular lower border defects are likely to hap-

pen after large mandibular advancement. The results in this study

show a considerably reduced occurrence of this type of defect

using grafted BSSO.

http://dx.doi.org/10.1016/j.ijom.2017.02.1086

Evaluation of condylar positioning in bimaxillary

orthognathic surgery using intraoperative cone-beam

computed tomography

A. Contreras

∗

, J. Altschiller, A. Gantz, A. Barrera, N. Yanine,

R. Cosmelli, C. Gaete, J. Cifuentes

Faculty of Medicine, School of Dentistry Clínica Alemana –

Universidad del Desarrollo Clínica Alemana de Santiago,

Santiago, Chile

Background:

Bilateral sagittal split osteotomy (BSSO) consti-

tutes the most used surgical method in the treatment of dentofacial

deformities. Alterations in the condylar position, after the BSSO,

can lead to recurrence of postoperative malocclusions, tem-

poromandibular joint disorders (TMJ) and condylar resorption.

Nowadays, the use of intraoperative cone-beam would allow to

objectify the condylar position after the BSSO, avoiding deleteri-

ous effects on TMJ for wronged condylar positioning, optimising

masticatory efficiency, functionality and postoperative skeletal

stability.

Objectives:

Design a tomographic intraoperative control protocol,

with O-Arm cone-beam equipment, of condylar positioning in

BSSO on orthognathic surgery (OS) and evaluate its utility.

Methods:

Clinical prospective study made between July 2013

and August 2016 of 300 patients who underwent OS at the Oral

and Maxillofacial Unit, Faculty of Medicine, School of Dentistry

Clínica Alemana – Universidad del Desarrollo Clinica Alemana

Santiago, Chile. In operating room, after BSSO, with radiopro-

tection protocol, O-Arm cone-beam is used with multiplanar and

three-dimensional images. The condylar position is evaluated, and

if necessary, new repositioning and new control is made.

Conclusions:

The use of intraoperative cone-beam is a reliable

technique that allows performing an immediate diagnosis of wrong

condylar positioning in OS, avoiding future complications.

http://dx.doi.org/10.1016/j.ijom.2017.02.1087