Table of Contents Table of Contents
Previous Page  207 / 398 Next Page
Information
Show Menu
Previous Page 207 / 398 Next Page
Page Background

202

Fabrication of a silk fibroin-fish collagen membrane for

guided bone regeneration

C. Chankum

∗

, P. Pripatnanont, J. Meesane

Department of Oral and Maxillofacial Surgery, Faculty of

Dentistry, Prince of Songkla University, Hatyai, Songkhla,

Thailand

Background:

A collagen membrane has been the most widely

used resorbable barrier membrane in guided bone regeneration,

however, a membrane is collapsible and fast degradation. Silk

fibroin has been introduced for improving the properties of a

membrane due to its high mechanical strength, low immunogenic

responses, and economical advantage.

Objectives:

This study aimed to fabricate a resorbable barrier

membrane using the composite of silk fibroin and fish collagen

materials.

Methods:

A silk fibroin film was made of Bombyx Mori silk and

immobilisedwith collagen frombrown-banded bamboo shark skin

by chemical cross-linked. The silk fibroin films were hydrated

prior tensile test to select suitable formula before immobilisa-

tion with collagen. Then physical and mechanical properties were

evaluated to verify characteristics of a barrier membrane com-

pared with a commercial collagen membrane. The morphology

and structure of samples were characterised by scanning elec-

tron microscopy (SEM), Fourier transform infrared spectroscopy

(FTIR) and atomic force microscopy (AFM). The hydrophobic-

hydrophilic surface was assessed by water contact angle.

Findings:

The SEM examination demonstrated collagen fibril

structure covering silk fibroin film and differed from silk fibroin

film that showed smooth surface. The AFM demonstrated that

immobilised collagen on silk fibroin film showed rougher surface

with fibrils covering. The FTIR showed spectrumof peptide bonds.

The immobilised collagen on silk fibroin film demonstrated more

hydrophobic surface than silk fibroin film.

Conclusion:

The in-house immobilised collagen on silk fibroin

film has been developed at an economic cost and possesses

physical properties of a barrier membrane used for guided bone

regeneration.

http://dx.doi.org/10.1016/j.ijom.2017.02.687

The use of TissuePatch

TM

, a self-adhesive sealant film to

prevent postoperative vascular leakage after head and neck

surgery

L. Cheng

∗

, A. Tahim, S. Ali, J. Blanchard, L. Johnston,

H. Leung, A. Jones, C. Grant

St Bartholomews’s, the Royal London and Homerton University

Hospital, United Kingdom

Background:

Meticulous haemostasis is required during head

and neck surgery, to minimise the potentially devastating seque-

lae of postoperative bleeding. While its mainstay has been

sound surgical technique and the use of haemostatic agents

such as Surgicel

®

, recently self-adhesive, absorbable surgical

sealants (TissuePatch

TM

) have been used to minimise leakage

in neurosurgery and thoracic surgery. We present a case series

demonstrating its use in head and neck surgery.

Methods:

A retrospective case note review was conducted of all

patients undergoing head and neck procedures under a single sur-

geon in whom TissuePatch

TM

was used. Patient demographics,

nature of surgery and the type of patch were noted. Pre- and post-

operative haemoglobin (Hb) levels, postoperative drain output and

complications were recorded.

Results:

20 patients received the patch. 70%were female. Patients

mainly underwent parotid gland surgery (40%) and submandibular

gland surgery (30%). The mean preoperative Hb was 13.4 with

a mean postoperative drop of 1.4. Length of hospital stay was

1.6 days. 85% patients had drains placed, which were left

in situ

for 1.5 days with an average drainage of 27.5 mL. No patients

required blood transfusion. One patient suffered a postoperative

haematoma requiring surgical exploration.

Conclusion:

We have found that the use of TissuePatch

TM

was a

safe adjunct to ensure an effective seal to the potential sources of

oozing or bleeding from the head and neck operative site. It was

versatile, easy to handle and apply, adapting easily to the vascular

bed on which it was placed.

http://dx.doi.org/10.1016/j.ijom.2017.02.688

Salivary lithiasis intraductal fragmentation with

stonebreaker and sterile sheet

C. Chossegros

∗

, J.M. Foletti, N. Graillon, P.A. Oddon

Oral and Maxillofacial Department Conception University

Hospital, Marseilles, France

Background:

1% of the main salivary gland are obstructed by cal-

culus. Minimally invasive surgery has been developed to remove

these calculus, preserve the glands and decrease the morbidity

Objectives:

Sialendoscopy with Stonebreaker (SB) intraductal

calculus fragmentation has recently been available. We report our

indication, experience with this technique and added an improve-

ment with use in a sterile sheet.

Methods:

Submandibular and parotid glands lithiases have been

treated with SB in a sterile sheet.

Findings and Conclusion:

Sialendoscopy with SB and sterile

sheet was efficient to treat our patients suffering from impacted

submandibular and parotid calculus. The use of a sterile sheet

helps to operate several patients in the same day with only one

SB handpiece. For submandibular gland, the duration of sialen-

doscopy with SB fragmentation was longer than with a transoral

calculus removal (62 nm versus 40 nm). For parotid gland sialen-

doscopy with SB use avoided to do a combined approach and to

open the skin. A mean of 47 impacts was delivered to the cal-

culus. The use of a sterile sheet does not extend the procedure

duration except in complicated cases when more than 80 impacts

are delivered, needing to change the cartridge. For main salivary

gland impacted calculus, sialendoscopy with SB fragmentation in

a sterile sheet is efficient, more conservative, than other techniques

and must be recommendable.

http://dx.doi.org/10.1016/j.ijom.2017.02.689