101
hydroxyapatite coated implant systemwas employed in this study.
The patients were followed up for a median of 31.3 months (range,
4 to 103 months).
Results:
There were no failures in the cases of immediate implant
placement.
Findings and Conclusions:
Originally, there was quite a dif-
ference in the shape between extraction socket and implant, so
a certain consideration for implant site selection was needed to
establish the initial fixation. Furthermore, meticulous cleaning,
socket curettage/debridement was also necessary to remove infec-
tious areas in extraction sockets of the compromised teeth. Finally,
successful immediate implant placement would be promised when
fulfilling certain inclusion criteria.
http://dx.doi.org/10.1016/j.ijom.2017.02.356Rehabilitation of atrophic maxilla by means of Le Fort I
osteotomy, zygomatic implants and immediate loading: a
report of three cases
M. Soares
∗
, C. Caminero
Osteogenesis/SENAC, Brazil
Background:
The rehabilitation of atrophic maxilla is a challenge
for maxillofacial surgeons. Bone grafts, short implants zygomatic
fixtures, has show good results, however on maxillary atrophy
associated with hypoplasia, anterior cant lever can lead the reha-
bilitation to mechanical failure.
Objective:
The aim of this paper is to report the surgical protocol
adopted to the correction of edentulous atrophic and hypoplastic
maxilla.
Methods:
Three patients (one male and two females) with sagittal
maxillary deficiency and class V (Cawwod and Howell) alveolar
atrophy were selected. The patients were rehabilitated by means
of Le Fort I osteotomy associated with zygomatic implants and
immediate loading. All patients were able to receive fixed pros-
thesis 3 days after the surgery.
Results:
All implants remain healthy and in function. One pros-
thesis required maintenance on the abutments screws six months
after surgery, after that no other problem occurred.
Conclusion:
Maxillary reposition by Le Fort I osteotomy associ-
ated with zygomatic implants can be an alternative to bone grafts
on rehabilitation of atrophic maxilla with maxillomandibular dis-
repancy.
http://dx.doi.org/10.1016/j.ijom.2017.02.357An inventory of mandibular fractures associated in atrophic
edentulous mandibles
A. Soehardi
∗
, G. Meijer, P. Stoelinga
Radboudumc, Nijmegen, The Netherlands
Background:
All clinicians are aware of several patients with
broken mandibles after implant placement in whom the fractures
occurred immediately after or several years following the initial
implant treatment.
Objectives:
To make an inventory of the number of fractures,
that occurred in conjunction with implants, placed in edentulous
patients in the Dutch population, in a given time period and to
calculate the incidence with which this might occur.
Methods:
questionnaires were send to all 198 oral and maxillo-
facial (OMF) surgeons, working in 56 hospitals with departments
of OMF Surgery in the Netherlands.
Results:
A response was received from 53 (95%) departments.
During the period 1980–2007, a total of 157 edentulous mandibles
were fractured pertaining to implant treatment. All fractures
occurred in mandibles of less than 10 mm high as measured in
the symphysis. An incidence of 0.033% was calculated based on a
total number of 475,000 patients treated with at least 2 implants in
the same period to support an overdenture. Reasons for implants
loss within one year (58%), included: ‘bone height too low, iatro-
genic cause, non-integration and jaw too narrow. Peri-implantitis,
trauma, explantation were related to fractures which occurred one
year or later after implant placement.
Conclusions:
This study supports the view that mandibles with
a height of 10 mm or less, as measured in the symphysis, are at
risk for fractures with a fair chance of serious complications as a
result of it. It also stresses the need for proper information about
the advantages and disadvantages of implants in thin mandibles.
http://dx.doi.org/10.1016/j.ijom.2017.02.358L
ong-term treatment outcome of dental implants placed after
sinuslift using novel fully autologous Plasma-Therm
material: pilot study
A. Stamatoski
∗
, J. Fidoski, F. Kasapi
Faculty of Dental Medicine Skopje Sts Cyril and Methodius
University, Skopje, Macedonia
Background:
The placement of dental implant in the edentulous
posterior maxilla often present difficulties as a result of insuffi-
cient bone due to pneumatisation of the maxillary sinus and bone
resorption after extraction. During sinus augmentation different
grafting material (GM) can be used for sinus membrane (SM) ele-
vation. Few types of autologous materials are available for this
procedure. Recently, we have developed new Plasma-Therm pro-
tocol for production of new (fully autologous) graft material and
barrier membrane.
Objectives:
Evaluate the predictability of new bone formation at
sinus floor after elevation of the membrane using a novel fully
autologous Plasma-Therm graft materials (NPTGM) for the first
time.
Methods:
In this study were included twenty sinus lifts selected
for implant placement in the edentulous posterior maxilla. Clini-
cal examination, cast preparation, and radiographic examination
(panoramic, cone-beam computed tomography) were performed.
Under local anaesthesia, SM was elevated through lateral window
technique and it was supported and maintained with a NPTGM.
Immediate postoperative clinical and radiographic examination
was performed for evaluation. Six month postoperatively, core
bone biopsy was performed for histological examination of the
formed bone using a trephine drill on two points around the placed
implant.
Results:
None of the patients showed any signs of dehiscence,
infection, or sinusitis. New bone formation was proven radiog-
raphy, histologically and clinically after implant placement and
using of the NPTGM.
Conclusion:
The new developed material was reliable and pre-
dictable as a grafting material after SM elevation.
http://dx.doi.org/10.1016/j.ijom.2017.02.359




